Literature DB >> 12489646

Effect of physical vapor deposition on cutting efficiency of nickel-titanium files.

Edgar Schäfer1.   

Abstract

The purpose of this study was to investigate possible changes in cutting efficiency of nickel-titanium K-files that had undergone physical vapor deposition coating. Titanium nitride coatings were deposited using different process parameters. A total of 84 nickel-titanium K-files (size 35) were randomly divided into 7 groups of 12 instruments each. Groups A to F (experimental): instruments were coated with titanium nitride using different process parameters regarding substrate temperature, applied voltage, coating thickness, and ion bombardment. Group K (control): samples were not coated with titanium nitride. The cutting efficiency of all instruments was determined in a rotary working motion by means of a computer-driven testing device. Special plastic samples with a cylindrical canal were used, and the maximum penetration depth of the instruments into the lumen was the criterion for cutting efficiency. Instruments of groups A, F, and C achieved significantly greater penetration depths than the uncoated instruments of the control group (p < 0.05). Cutting efficiency of physical vapor deposition-coated nickel-titanium files was increased by up to 26.2% in comparison with uncoated instruments.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12489646     DOI: 10.1097/00004770-200212000-00002

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Effect of cryogenic treatment on nickel-titanium endodontic instruments.

Authors:  J W Kim; J A Griggs; J D Regan; R A Ellis; Z Cai
Journal:  Int Endod J       Date:  2005-06       Impact factor: 5.264

2.  An in vitro evaluation of the effect of deep dry cryotreatment on the cutting efficiency of three rotary nickel titanium instruments.

Authors:  Gingu Koshy George; Kavitha Sanjeev; Mahalaxmi Sekar
Journal:  J Conserv Dent       Date:  2011-04

Review 3.  A Review of the Various Surface Treatments of NiTi Instruments.

Authors:  Zahed Mohammadi; Mohammad Karim Soltani; Sousan Shalavi; Saeed Asgary
Journal:  Iran Endod J       Date:  2014-10-07

4.  Surface and cross-sectional characterization of titanium-nitride coated nickel-titanium endodontic files.

Authors:  Youssef S Al Jabbari; Theodoros Koutsoukis; Suliman Al Hadlaq; David W Berzins; Spiros Zinelis
Journal:  J Dent Sci       Date:  2015-11-19       Impact factor: 2.080

Review 5.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

6.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27
  6 in total