Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implantable drop-foot stimulator.

P H Veltink1, P Slycke, J Hemssems, R Buschman, G Bultstra, H Hermens.   

Abstract

A three dimensional inertial sensing system for measuring foot movements during gait is proposed and tested. It can form the basis for an automated tuning system for a two-channel implantable drop-foot stimulator. The foot orientation and position during the swing phase of gait can be reconstructed on the basis of three-dimensional measurement of acceleration and angular velocity, using initial and final conditions during mid-stance. The foot movements during gait of one stroke person using the implanted two-channel stimulator were evaluated for several combinations of stimulation parameters for both channels. The reconstructed foot movements during gait in this person indicated that the channel stimulating the deep peroneal nerve contributes mainly to dorsiflexion and provides some reduction of inversion seen without stimulation, while the channel activating the superficial peroneal nerve mainly provides additional reduction of inversion. This agrees with anatomical knowledge about the function of the muscles activated by both branches of the peroneal nerve. The inertial sensor method is expected to be useful for the clinical evaluation of foot movements during gait supported by the two-channel drop-foot stimulator. Furthermore, it is expected to be applicable for the automated balancing of the two stimulation channels to ensure optimal support of gait.

Entities:  

Mesh:

Year:  2003        PMID: 12485783     DOI: 10.1016/s1350-4533(02)00041-3

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  10 in total

1.  Quaternion-based strap-down integration method for applications of inertial sensing to gait analysis.

Authors:  A M Sabatini
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

2.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers.

Authors:  H J Luinge; P H Veltink
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

3.  Reliability and validity of a wireless microelectromechanicals based system (keimove™) for measuring vertical jumping performance.

Authors:  Bernardo Requena; Inmaculada García; Francisco Requena; Eduardo Saez-Saez de Villarreal; Mati Pääsuke
Journal:  J Sports Sci Med       Date:  2012-03-01       Impact factor: 2.988

4.  A wearable inertial measurement unit for long-term monitoring in the dependency care area.

Authors:  Daniel Rodríguez-Martín; Carlos Pérez-López; Albert Samà; Joan Cabestany; Andreu Català
Journal:  Sensors (Basel)       Date:  2013-10-18       Impact factor: 3.576

5.  Height compensation using ground inclination estimation in inertial sensor-based pedestrian navigation.

Authors:  Sang Kyeong Park; Young Soo Suh
Journal:  Sensors (Basel)       Date:  2011-08-15       Impact factor: 3.576

6.  Bilateral step length estimation using a single inertial measurement unit attached to the pelvis.

Authors:  Alper Köse; Andrea Cereatti; Ugo Della Croce
Journal:  J Neuroeng Rehabil       Date:  2012-02-08       Impact factor: 4.262

7.  Motor neuroprosthesis for promoting recovery of function after stroke.

Authors:  Luciana A Mendes; Illia Ndf Lima; Tulio Souza; George C do Nascimento; Vanessa R Resqueti; Guilherme Af Fregonezi
Journal:  Cochrane Database Syst Rev       Date:  2020-01-14

8.  Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait.

Authors:  Diana Trojaniello; Andrea Cereatti; Elisa Pelosin; Laura Avanzino; Anat Mirelman; Jeffrey M Hausdorff; Ugo Della Croce
Journal:  J Neuroeng Rehabil       Date:  2014-11-11       Impact factor: 4.262

9.  Estimation of Foot Trajectory and Stride Length during Level Ground Running Using Foot-Mounted Inertial Measurement Units.

Authors:  Yuta Suzuki; Michael E Hahn; Yasushi Enomoto
Journal:  Sensors (Basel)       Date:  2022-09-20       Impact factor: 3.847

10.  Robust Foot Clearance Estimation Based on the Integration of Foot-Mounted IMU Acceleration Data.

Authors:  Mourad Benoussaad; Benoît Sijobert; Katja Mombaur; Christine Azevedo Coste
Journal:  Sensors (Basel)       Date:  2015-12-23       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.