Intra-observer and inter-observer repeatability of anterior eye segment analysis system (EAS-1000) in anterior chamber configuration.

Andrew K C Lam1, Rufina Chan, George C Woo, Peter C K Pang, Roger Chiu.   

Abstract

BACKGROUND: Anterior chamber configuration can be assessed via optical or ultrasonic techniques. Scheimpflug photography is a non-invasive method measuring the anterior segment. The Anterior Eye Segment analysis system, EAS-1000, utilises the Scheimpflug principle and was found to have good repeatability. Previous repeatability studies, however, have had limitations in their design. The current study investigated the intra-observer and interobserver repeatability of the EAS-1000.
METHODS: Twenty-five healthy young subjects were recruited. The anterior chamber angles in different quadrants were measured by two examiners for interobserver analysis. The first examiner repeated the measurement at another session for intra-observer analysis. The 95% limits of agreement and intra-class correlation coefficient (ICC) were calculated. The anterior chamber depth was also measured and compared with ultrasound biometry.
RESULTS: The anterior chamber angle assessment demonstrated good intra-observer (ICC ranging from 0.77 to 0.90 for different quadrants) and interobserver (ICC ranging from 0.68 to 0.81 for different quadrants) repeatability. The 95% intra-observer limits of agreement were within +/-5 degrees. The 95% interobserver limits of agreement were within +/-6 degrees. There was no significant difference between male and female subjects or among angles at different quadrants. The anterior chamber depth was found to be repeatable (ICC > 0.90) with 95% limits of agreement +/-0.1 mm. The anterior chamber depth was shallower than that obtained from ultrasound biometry.
CONCLUSIONS: The EAS-100 is a non-invasive instrument which is repeatable for measuring the anterior chamber angle and depth. It provides quick results and is good for screening purposes. There is an under-estimation of anterior chamber depth, as previously reported.

Mesh:

Year:  2002        PMID: 12477020     DOI: 10.1046/j.1475-1313.2002.00074.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  4 in total

1.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

2.  Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry.

Authors:  Jeevan S Ladi; Nitant A Shah
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

Review 3.  Angle imaging: advances and challenges.

Authors:  Desmond T L Quek; Monisha E Nongpiur; Shamira A Perera; Tin Aung
Journal:  Indian J Ophthalmol       Date:  2011-01       Impact factor: 1.848

4.  Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis.

Authors:  Rajeev Jain; Grewal Dilraj; Satinder Pal Singh Grewal
Journal:  Indian J Ophthalmol       Date:  2007 Sep-Oct       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.