Literature DB >> 12476985

Calculation of the x-ray film response to heavy charged particle irradiation.

B Spielberger1, M Scholz, M Krämer, G Kraft.   

Abstract

A model was developed to calculate the response of films to heavy ion irradiation as a function of particle type and energy. It is based on the local effect model and was extended to be applied to the non-homogeneous target of photographic emulsions. The calculation was performed for protons and carbon ions in the energy range from 2 to 430 MeV u(-1). The calculated film responses are in very good agreement with experimental data. Based on this model calculation a data base of film responses was set up. This enables a three-dimensional dose verification with films in the heavy ion tumour therapy project at GSI, Darmstadt.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12476985     DOI: 10.1088/0031-9155/47/22/313

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A track structure model for simulation of strand breaks in plasmid DNA after heavy ion irradiation.

Authors:  S Brons; G Taucher-Scholz; M Scholz; G Kraft
Journal:  Radiat Environ Biophys       Date:  2003-03-12       Impact factor: 1.925

2.  Scanned carbon beam irradiation of moving films: comparison of measured and calculated response.

Authors:  Christoph Bert; Daniel Richter; Marco Durante; Eike Rietzel
Journal:  Radiat Oncol       Date:  2012-04-02       Impact factor: 3.481

3.  Validation of dosimetric field matching accuracy from proton therapy using a robotic patient positioning system.

Authors:  Jonathan B Farr; Avril O'Ryan-Blair; Frederick Jesseph; Wen-Chien Hsi; Chris E Allgower; Anthony E Mascia; Allan F Thornton; Andreas N Schreuder
Journal:  J Appl Clin Med Phys       Date:  2010-04-12       Impact factor: 2.102

4.  Radiographic film dosimetry of proton beams for depth-dose constancy check and beam profile measurement.

Authors:  Inhwan J Yeo; Anthony Teran; Abiel Ghebremedhin; Matt Johnson; Baldev Patyal
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

5.  A Modular System for Treating Moving Anatomical Targets With Scanned Ion Beams at Multiple Facilities: Pre-Clinical Testing for Quality and Safety of Beam Delivery.

Authors:  Michelle Lis; Wayne Newhauser; Marco Donetti; Moritz Wolf; Timo Steinsberger; Athena Paz; Marco Durante; Christian Graeff
Journal:  Front Oncol       Date:  2021-03-19       Impact factor: 6.244

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.