Abstract
OBJECTIVE: To evaluate the Haemoglobin Colour Scale developed by WHO for estimating haemoglobin concentration and to compare the results obtained using it and the HemoCue assay with those determined using a reference method, the Technicon H3 analyser. METHODS: The Colour Scale and HemoCue assay were used to test 408 blood samples. Subsequently, Bland-Altman plots were determined and the proximity of the test results to those obtained using the reference method was determined. FINDINGS: The mean difference between the Haemoglobin Colour Scale and the reference method was 0.19 g/dl (95% confidence interval: 3.50 g/dl below to 3.11 g/dl above); the corresponding value for the HemoCue assay was 0.50 g/dl (1.16 g/dl below to 0.16 g/dl above). Only 46.08% of the results obtained by means of the Colour Scale were within 1.0 g/dl of the reference method, whereas 95.34% of the HemoCue results fell within this limit; 22.79% of the Colour Scale results but none of the HemoCue results lay more than 2.0 g/dl from the reference method. CONCLUSION: The Haemoglobin Colour Scale test is too inaccurate for general use, particularly if devices such as the HemoCue are available.
OBJECTIVE: To evaluate the Haemoglobin Colour Scale developed by WHO for estimating haemoglobin concentration and to compare the results obtained using it and the HemoCue assay with those determined using a reference method, the Technicon H3 analyser. METHODS: The Colour Scale and HemoCue assay were used to test 408 blood samples. Subsequently, Bland-Altman plots were determined and the proximity of the test results to those obtained using the reference method was determined. FINDINGS: The mean difference between the Haemoglobin Colour Scale and the reference method was 0.19 g/dl (95% confidence interval: 3.50 g/dl below to 3.11 g/dl above); the corresponding value for the HemoCue assay was 0.50 g/dl (1.16 g/dl below to 0.16 g/dl above). Only 46.08% of the results obtained by means of the Colour Scale were within 1.0 g/dl of the reference method, whereas 95.34% of the HemoCue results fell within this limit; 22.79% of the Colour Scale results but none of the HemoCue results lay more than 2.0 g/dl from the reference method. CONCLUSION: The Haemoglobin Colour Scale test is too inaccurate for general use, particularly if devices such as the HemoCue are available.
Authors: Erika A Tyburski; Scott E Gillespie; William A Stoy; Robert G Mannino; Alexander J Weiss; Alexa F Siu; Rayford H Bulloch; Karthik Thota; Anyela Cardenas; Wilena Session; Hanna J Khoury; Siobhán O'Connor; Silvia T Bunting; Jeanne Boudreaux; Craig R Forest; Manila Gaddh; Traci Leong; L Andrew Lyon; Wilbur A Lam Journal: J Clin Invest Date: 2014-08-26 Impact factor: 14.808
Authors: Patrick T McGann; Erika A Tyburski; Vysolela de Oliveira; Brigida Santos; Russell E Ware; Wilbur A Lam Journal: Am J Hematol Date: 2015-10-12 Impact factor: 10.047
Authors: Andry Van de Louw; Nadine Lasserre; François Drouhin; Stéphane Thierry; Lucien Lecuyer; Daniel Caen; Alain Tenaillon Journal: Intensive Care Med Date: 2006-12-05 Impact factor: 17.440
Authors: Danièle Kedy Koum; Eveline Ngouadjeu Dongho Tsakeu; Françoise Ngo Sack; Pierre Tchienrg Moueleu Ngalagou; Albert Kamanyi; Samuel Honoré Mandengue Journal: Pan Afr Med J Date: 2013-11-11