Comparing imperfect measurements with the Bland-Altman technique: application in gene expression analysis.

Lucila Ohno-Machado1, Staal Vinterbo, Stephen Dreiseitl, Tor-Kristian Jenssen, Winston Kuo.   

Abstract

Several problems in medicine and biology involve the comparison of two measurements made on the same set of cases. The problem differs from a calibration problem because no gold standard can be identified. Testing the null hypothesis of no relationship using measures of association is not optimal since the measurements are made on the same cases, and therefore correlation coefficients will tend to be significant. The descriptive Bland-Altman method can be used in exploratory analysis of this problem, allowing the visualization of gross systematic differences between the two sets of measurements. We utilize the method on three sets of matched observations and demonstrate its usefulness in detecting systematic variations between two measurement technologies to assess gene expression.

Mesh:

Substances:

Year:  2002        PMID: 12463888      PMCID: PMC2244491     

Source DB:  PubMed          Journal:  Proc AMIA Symp        ISSN: 1531-605X


  7 in total

1.  The reliability of vital sign measurements.

Authors:  Zachary V Edmonds; William R Mower; Luis M Lovato; Rosaelva Lomeli
Journal:  Ann Emerg Med       Date:  2002-03       Impact factor: 5.721

2.  State-of-the-art ultrasonography is as accurate as helical computed tomography and computed tomographic angiography for detecting unresectable periampullary cancer.

Authors:  M M Morrin; J B Kruskal; V Raptopoulos; K Weisinger; R J Farrell; M L Steer; R A Kane
Journal:  J Ultrasound Med       Date:  2001-05       Impact factor: 2.153

3.  A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement.

Authors:  J M Bland; D G Altman
Journal:  Comput Biol Med       Date:  1990       Impact factor: 4.589

4.  Power Doppler imaging of carotid artery stenosis. Comparison with color Doppler flow imaging and angiography.

Authors:  W Steinke; S Ries; N Artemis; A Schwartz; M Hennerici
Journal:  Stroke       Date:  1997-10       Impact factor: 7.914

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Quantification of vascular density using a semiautomated technique for immunostained specimens.

Authors:  Timothy W King; Eric M Brey; Adel A Youssef; Carol Johnston; Charles W Patrick
Journal:  Anal Quant Cytol Histol       Date:  2002-02       Impact factor: 0.302

7.  Analysis of matched mRNA measurements from two different microarray technologies.

Authors:  Winston Patrick Kuo; Tor-Kristian Jenssen; Atul J Butte; Lucila Ohno-Machado; Isaac S Kohane
Journal:  Bioinformatics       Date:  2002-03       Impact factor: 6.937

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.