Literature DB >> 12456438

Falsely increased bispectral index during endoscopic shoulder surgery attributed to interferences with the endoscopic shaver device.

Thomas M Hemmerling1, Brigitte Migneault.   

Abstract

IMPLICATIONS: Endoscopic shaver activity can cause falsely increased bispectral index (BIS) readings. Close observation of BIS during periods with no shaver activity will reveal the true BIS and can be used to titrate depth of anesthesia. The reason for these interferences remain unclear.

Mesh:

Year:  2002        PMID: 12456438     DOI: 10.1097/00000539-200212000-00038

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  11 in total

1.  Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery.

Authors:  Sang Wook Lee; Soo Eun Choi; Jin Hee Han; Sung-Wook Park; Wha Ja Kang; Young Kyoo Choi
Journal:  Korean J Anesthesiol       Date:  2014-10-27

Review 2.  Automation of anaesthesia: a review on multivariable control.

Authors:  Jing Jing Chang; S Syafiie; Raja Kamil; Thiam Aun Lim
Journal:  J Clin Monit Comput       Date:  2014-06-25       Impact factor: 2.502

3.  Inappropriate elevation of bispectral index values in robot assisted thyroidectomy with electromyographic endotracheal tube -A case report-.

Authors:  Mae-Hwa Kang; Chi-Bum In; Man-Ho Kim; Kyoung-Ji Lim; Eun Young Park; Hyo Min Lee; Soo Kyung Lee
Journal:  Korean J Anesthesiol       Date:  2011-12-20

4.  Validation of the patient State Index for monitoring sedation state in critically ill patients: a prospective observational study.

Authors:  Masafumi Idei; Yusuke Seino; Nobuo Sato; Takuya Yoshida; Yumi Saishu; Kimiya Fukui; Masahiro Iwabuchi; Junya Ishikawa; Kei Ota; Daigo Kamei; Masashi Nakagawa; Takeshi Nomura
Journal:  J Clin Monit Comput       Date:  2022-06-04       Impact factor: 2.502

5.  Awareness during anaesthesia.

Authors:  K Sandhu; Hh Dash
Journal:  Indian J Anaesth       Date:  2009-04

6.  Unusual elevation in Entropy but not in PSI during general anesthesia: a case report.

Authors:  Young Sung Kim; Dongik Chung; Seok Kyeong Oh; Young Ju Won; Il Ok Lee
Journal:  BMC Anesthesiol       Date:  2018-02-14       Impact factor: 2.217

7.  Influence of electrocautery-induced electromagnetic interference on quantitative electroencephalographic monitoring of hypnosis during general anesthesia: comparison between the ADMS® and the BIS VISTATM.

Authors:  Dae-Hee Kim; Ji-Young Yoo; Jong-Yeop Kim; Soo-Hwan Ahn; Seongsu Kim; Sang-Kee Min
Journal:  Korean J Anesthesiol       Date:  2018-04-24

8.  Selection of the Best Electroencephalogram Channel to Predict the Depth of Anesthesia.

Authors:  Clement Dubost; Pierre Humbert; Arno Benizri; Jean-Pierre Tourtier; Nicolas Vayatis; Pierre-Paul Vidal
Journal:  Front Comput Neurosci       Date:  2019-10-01       Impact factor: 2.380

9.  Interruption of bispectral index monitoring by nerve integrity monitoring during tympanoplasty -A case report-.

Authors:  Jun Hyun Kim; Ah Na Kim; Kyung Woo Kim; Sang-Il Lee; Ji Yeon Kim; Kyung-Tae Kim; Jang Su Park; Jung Won Kim; Won Joo Choe
Journal:  Korean J Anesthesiol       Date:  2013-02-15

10.  Falsely increased bispectral index values by convective air warming system during kidney transplantation.

Authors:  Se Hun Kim; Byeong-Cheol Lee; Yong Han Kim
Journal:  Pak J Med Sci       Date:  2016 May-Jun       Impact factor: 1.088

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.