Abstract

AIM: The aim of this study was to compare the preparation of oval distal root canals in mandibular molars using three different nickel-titanium (NiTi) instruments: Lightspeed (Lightspeed Inc., San Antonio, TX, USA). ProFile .04 (Maillefer Ballaigues. Switzerland) and Quantec SC (Tycom, Irvine, CA, USA).
METHODOLOGY: Three groups of 20 extracted mandibular molars with oval distal root canals were embedded in a muffle system as described by Bramante et al. (1987) and modified by Hülsmann et al. (1999). Preparation of the root canals was performed with particular emphasis on the buccal and lingual extensions of the oval shape. The following parameters were evaluated: comparison of pre- and postoperative photographs with regard to the buccal and lingual extensions of the preparation, safety issues (file fractures, perforations, apical blockages, loss of working length), cleaning ability (SEM investigated using a 5-score system for remaining debris and smear layer) and working time.
RESULTS: Superimposition of pre- and postoperative cross-sections in the majority of specimens revealed uninstrumented or incompletely instrumented buccal or lingual extensions (Lightspeed and Quantec SC, 56.7%; ProFile .04, 55%) For debris removal, Quantec SC achieved the best results (54.2% scores 1 and 2), followed by ProFile .04 (52.5%) and Lightspeed (46.7%). Preparation resulted in substantial smear layer covering the canal walls for every system (ProFile .04, 38.3%; Quantec SC, 36.6%; Lightspeed, 28.3%). Differences between the three systems were not significant for any of the parameters investigated. Preparation with Lightspeed resulted in two fractured instruments; with Quantec SC. two apical blockages occurred. With ProFile .04, no complications were noticed. Mean working time was shorter for ProFile .04 (261.2 s) than for Quantec SC (272.4 s) and Lightspeed (338.9 s); the differences were not significant.
CONCLUSIONS: The flexibility of the NiTi instruments investigated in this study did not allow controlled preparation of the buccal and lingual extensions of oval root canals. The instruments frequently produced a circular bulge in the canal whilst the buccal and lingual extensions remained unprepared, leaving smear layer and debris.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12453021     DOI: 10.1046/j.1365-2591.2002.00599.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  10 in total

1.  Apical debris extrusion associated with oval shaped canals: a comparative study of WaveOne vs Self-Adjusting File.

Authors:  Eleftherios Terry R Farmakis; G G Sotiropoulos; I Abràmovitz; M Solomonov
Journal:  Clin Oral Investig       Date:  2016-01-12       Impact factor: 3.573

2.  Apical extrusion of debris during the preparation of oval root canals: a comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file.

Authors:  Anda Kfir; Rotem Moza-Levi; Moran Herteanu; Amir Weissman; Ronald Wigler
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

3.  The influence of the irrigant QMix on the push-out bond strength of a bioceramic endodontic sealer.

Authors:  Mustafa Gündoğar; Güzide Pelin Sezgin; Erhan Erkan; Özgün Yusuf Özyılmaz
Journal:  Eur Oral Res       Date:  2018-05-01

4.  In vitro evaluation of root canal preparation using oscillatory and rotary systems in flattened root canals.

Authors:  Luis Cardoso Rasquin; Fabíola Bastos de Carvalho; Regina Karla de Pontes Lima
Journal:  J Appl Oral Sci       Date:  2007-02       Impact factor: 2.698

5.  Effect of ultrasound streaming on the disinfection of flattened root canals prepared by rotary and reciprocating systems.

Authors:  Layla Reginna Silva Munhoz de Vasconcelos; Raquel Zanin Midena; Paloma Gagliardi Minotti; Thais Cristina Pereira; Marco Antonio Hungaro Duarte; Flaviana Bombarda de Andrade
Journal:  J Appl Oral Sci       Date:  2017 Sep-Oct       Impact factor: 2.698

6.  Comparison of the cleaning efficacy of XP-endo shaper and Mtwo rotary files in oval-shaped canals.

Authors:  Narges Simdar; Nazanin Bashardoust; Majid Jahangir
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10

7.  Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

Authors:  Vicente Faus-Llácer; Nicolás Collado-Castellanos; Teresa Alegre-Domingo; María Dolz-Solsona; Vicente Faus-Matoses
Journal:  J Clin Exp Dent       Date:  2015-04-01

8.  Assessment Using AutoCAD Software of the Preparation of Dentin Walls in Root Canals Produced by 4 Different Endodontic Instrument Systems.

Authors:  Cristina Cabanillas; Manuel Monterde; Antonio Pallarés; Susana Aranda; Raquel Montes
Journal:  Int J Dent       Date:  2015-11-18

9.  Spatial Cleaning Action of Ultrasonic Irrigation on Enterococcus faecalis Biofilm.

Authors:  Michael C C Tse; Gary S P Cheung
Journal:  Dent J (Basel)       Date:  2020-05-07

10.  Prevalence of Different Types of Apical Root Canal Morphology and their Treatment Recommendations in an Institute.

Authors:  Sushmita Shrestha; Smriti Karki; Navin Agrawal; Mannu Vikram; Vimmi Singh; Ashish Shrestha
Journal:  JNMA J Nepal Med Assoc       Date:  2018 Mar-Apr       Impact factor: 0.406

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.