Literature DB >> 12451756

ROBITOM-robot for biopsy and therapy of the mamma.

A Felden1, J Vagner, A Hinz, H Fischer, S O R Pfleiderer, J R Reichenbach, W A Kaiser.   

Abstract

MR-Mammography reaches a high sensitivity in detecting breast carcinomas of 3 mm in size at least. In cooperation with the Institute of Diagnostic and Interventional Radiology of the Friedrich-Schiller-University of Jena, a manipulator has been developed by the IMB, which combines the advantages of MRM imaging with a minimal invasive biopsy and a possible subsequent therapy. Referring to this ROBITOM I was introduced in November 1999 as worldwide first, precise operating manipulator system in the ISO center of a closed MR, at RSNA in Chicago. Clinical trials started at 22. November 2000. The experiences and results of these tests were brought into the following prototype ROBITOM II, that is currently developed at the IMB. The completion of this Prototype is planned at the end of 2002.

Entities:  

Mesh:

Year:  2002        PMID: 12451756     DOI: 10.1515/bmte.2002.47.s1a.2

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  13 in total

1.  MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

Authors:  Gregory S Fischer; Iulian Iordachita; Csaba Csoma; Junichi Tokuda; Simon P Dimaio; Clare M Tempany; Nobuhiko Hata; Gabor Fichtinger
Journal:  IEEE ASME Trans Mechatron       Date:  2008-06-01       Impact factor: 5.303

2.  An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention.

Authors:  Axel Krieger; Iulian I Iordachita; Peter Guion; Anurag K Singh; Aradhana Kaushal; Cynthia Ménard; Peter A Pinto; Kevin Camphausen; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2011-11       Impact factor: 4.538

3.  MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking.

Authors:  Roberto Blanco Sequeiros; Heli Reinikainen; Andreas M Blanco Sequeiros; Teuvo Vaara; Risto Ojala; Eija Pääkkö; Osmo Tervonen
Journal:  Eur Radiol       Date:  2006-09-22       Impact factor: 5.315

4.  Multi-imager compatible actuation principles in surgical robotics.

Authors:  D Stoianovici
Journal:  Int J Med Robot       Date:  2005-01       Impact factor: 2.547

5.  Robotic image-guided needle interventions of the prostate.

Authors:  Pierre C Mozer; Alan W Partin; Dan Stoianovici
Journal:  Rev Urol       Date:  2009

6.  MRI compatibility of robot actuation techniques--a comparative study.

Authors:  Gregory S Fischer; Axel Krieger; Iulian Iordachita; Csaba Csoma; Louis L Whitcomb; Fichtinger Gabor
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

7.  Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.

Authors:  Gregory S Fischer; Iulian Iordachita; Csaba Csoma; Junichi Tokuda; Philip W Mewes; Clare M Tempany; Nobuhiko Hata; Gabor Fichtinger
Journal:  IEEE Int Conf Robot Autom       Date:  2008-06-13

8.  "MRI Stealth" robot for prostate interventions.

Authors:  Dan Stoianovici; Danny Song; Doru Petrisor; Daniel Ursu; Dumitru Mazilu; Michael Muntener; Michael Mutener; Michael Schar; Alexandru Patriciu
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

Review 9.  Advancements in magnetic resonance-guided robotic interventions in the prostate.

Authors:  Katarzyna J Macura; Dan Stoianovici
Journal:  Top Magn Reson Imaging       Date:  2008-12

Review 10.  Urologic robots and future directions.

Authors:  Pierre Mozer; Jocelyne Troccaz; Dan Stoianovici
Journal:  Curr Opin Urol       Date:  2009-01       Impact factor: 2.309

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.