Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers.

E H Cheyne1, D A Cavan, D Kerr.   

Abstract

It has been suggested that the continuous glucose monitoring system may be a useful tool for detecting unrecognised hypoglycaemia, especially at times when finger prick testing is difficult or impossible (e.g., at night). Studies suggest that subcutaneous glucose levels closely mimic blood glucose levels with a lag time of only a few minutes. However, no studies have been published to show how well the sensor performs during sustained or in recovery from hypoglycaemia. This study involved using a hyperinsulinaemic glucose clamp (60 mU/m2) in nine healthy volunteers. Each subject had two sensors inserted the day before the study. Blood glucose levels were maintained at euglycaemia for the first 60 min, then decreased to 45 mg/dL (2.5 mmol/L) for 60 min, and finally restored to euglycaemia. Blood glucose measurements were compared with interstitial values recorded by the sensor. Sensor profiles showed acceptable agreement with blood glucose levels at each of the three plateaus with a correlation coefficient of 0.79, slope of 0.85, and mean absolute error of 7%. The sensor drop closely matched the drop in blood glucose, but the recovery from hypoglycaemia was delayed by an average of 26 min. Continuous glucose sensing provides a useful means of detecting unrecognised hypoglycaemia in type 1 diabetes, although the duration of hypoglycaemia may be overestimated.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12450441     DOI: 10.1089/152091502320798222

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  16 in total

1.  Comparison of the numerical and clinical accuracy of four continuous glucose monitors.

Authors:  Boris Kovatchev; Stacey Anderson; Lutz Heinemann; William Clarke
Journal:  Diabetes Care       Date:  2008-03-13       Impact factor: 19.112

2.  Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring.

Authors:  Ulrike Holzinger; Joanna Warszawska; Reinhard Kitzberger; Harald Herkner; Philipp G H Metnitz; Christian Madl
Journal:  Intensive Care Med       Date:  2009-04-07       Impact factor: 17.440

3.  Real-time continuous glucose monitoring in the clinical setting: the good, the bad, and the practical.

Authors:  Irene Mamkin; Svetlana Ten; Sonal Bhandari; Neesha Ramchandani
Journal:  J Diabetes Sci Technol       Date:  2008-09

4.  Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Authors:  Peter H Kvist; Henrik E Jensen
Journal:  J Diabetes Sci Technol       Date:  2007-09

5.  Use of continuous glucose monitoring in the detection and prevention of hypoglycemia.

Authors:  Howard A Wolpert
Journal:  J Diabetes Sci Technol       Date:  2007-01

6.  Continuous Glucose Monitoring After Gastric Bypass to Evaluate the Glucose Variability After a Low-Carbohydrate Diet and to Determine Hypoglycemia.

Authors:  Joan Bach Nielsen; Caroline Bruun Abild; Ane Mathilde Pedersen; Steen Bønløkke Pedersen; Bjørn Richelsen
Journal:  Obes Surg       Date:  2016-09       Impact factor: 4.129

7.  Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia.

Authors:  G M Steil; K Rebrin; F Hariri; S Jinagonda; S Tadros; C Darwin; M F Saad
Journal:  Diabetologia       Date:  2005-07-07       Impact factor: 10.122

8.  In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes.

Authors:  Boris P Kovatchev; Marc Breton; Chiara Dalla Man; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2009-01

9.  Establishing a continuous glucose monitoring program.

Authors:  Howard Wolpert
Journal:  J Diabetes Sci Technol       Date:  2008-03

10.  Lack of accuracy of continuous glucose sensors in healthy, nondiabetic children: results of the Diabetes Research in Children Network (DirecNet) accuracy study.

Authors:  Nelly Mauras; Roy W Beck; Katrina J Ruedy; Craig Kollman; William V Tamborlane; H Peter Chase; Bruce A Buckingham; Eva Tsalikian; Stuart Weinzimer; Andrea D Booth; Dongyuan Xing
Journal:  J Pediatr       Date:  2004-06       Impact factor: 4.406

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.