Literature DB >> 12445618

Use of dual Euler angles to quantify the three-dimensional joint motion and its application to the ankle joint complex.

Ning Ying1, Wangdo Kim.   

Abstract

This paper presents a modified Euler angles method, dual Euler angles approach, to describe general spatial human joint motions. In dual Euler angles approach, the three-dimensional joint motion is considered as three successive screw motions with respect to the axes of the moving segment coordinate system; accordingly, the screw motion displacements are represented by dual Euler angles. The algorithm for calculating dual Euler angles from coordinates of markers on the moving segment is also provided in this study. As an example, the proposed method is applied to describe motions of ankle joint complex during dorsiflexion-plantarflexion. A Flock of Birds electromagnetic tracking device (FOB) was used to measure joint motion in vivo. Preliminary accuracy tests on a gimbal structure demonstrate that the mean errors of dual Euler angles evaluated by using source data from FOB are less than 1 degrees for rotations and 1mm for translations, respectively. Based on the pilot study, FOB is feasible for quantifying human joint motions using dual Euler angles approach.

Entities:  

Mesh:

Year:  2002        PMID: 12445618     DOI: 10.1016/s0021-9290(02)00241-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Multi-rigid image segmentation and registration for the analysis of joint motion from three-dimensional magnetic resonance imaging.

Authors:  Yangqiu Hu; William R Ledoux; Michael Fassbind; Eric S Rohr; Bruce J Sangeorzan; David Haynor
Journal:  J Biomech Eng       Date:  2011-10       Impact factor: 2.097

2.  New method of measuring wrist joint position sense avoiding cutaneous and visual inputs.

Authors:  Andre Gay; Kimberly Harbst; Kenton R Kaufman; Diana K Hansen; Edward R Laskowski; Richard A Berger
Journal:  J Neuroeng Rehabil       Date:  2010-02-10       Impact factor: 4.262

3.  Postural Stability Evaluation of Patients Undergoing Vestibular Schwannoma Microsurgery Employing the Inertial Measurement Unit.

Authors:  Patrik Kutilek; Zdenek Svoboda; Ondrej Cakrt; Karel Hana; Martin Chovanec
Journal:  J Healthc Eng       Date:  2018-04-18       Impact factor: 2.682

4.  Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation.

Authors:  Byong Hun Kim; Sae Yong Lee
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

5.  Quantification of Trunk Postural Stability Using Convex Polyhedron of the Time-Series Accelerometer Data.

Authors:  Roman Melecky; Vladimir Socha; Patrik Kutilek; Lenka Hanakova; Peter Takac; Jakub Schlenker; Zdenek Svoboda
Journal:  J Healthc Eng       Date:  2016       Impact factor: 2.682

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.