Literature DB >> 12432479

Complications of breast augmentation with injected hydrophilic polyacrylamide gel.

Ning-Xin Cheng1, Yuan-Lu Wang, Jin-Huang Wang, Xiao-Man Zhang, Hong Zhong.   

Abstract

Since 1997, the hydrophilic polyacrylamide gel (PAAG), an injectable alloplastic biomaterial, imported from the Ukraine has been used for augmentation mammaplasty in China. There were twelve patients with various complications visiting our hospitals after breast augmentation with injected hydrophilic polyacrylamide gel by other clinics, even though such procedures are not performed in our clinical practices. The complications included four cases of PAAG-induced multiple induration and lumps, and one with lactation, three cases of hematoma, two cases of inflammation (infection), and persistent mastodymia, unsatisfactory contour results and abnormal skin sensations in each case. All patients have been treated by removing the injected gel and giving antibiotics. Other procedures included replacement by silicon breast prostheses, mammotomy, and segmental mastectomy. We suggest that the injectable hydrophilic polyacrylamide gel be contraindications for breast augmentation in any young female who is not married, or without a child, with a tendency to hemorrhage, and with little mammary tissue. Some considerations to prevent and manage these complications are discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12432479     DOI: 10.1007/s00266-002-2052-4

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  22 in total

1.  Polyacrylamide gel injections for breast augmentation: management of complications in 106 patients, a multicenter study.

Authors:  Dmytro Unukovych; Vasyl Khrapach; Marie Wickman; Annelie Liljegren; Volodymyr Mishalov; Gennadiy Patlazhan; Kerstin Sandelin
Journal:  World J Surg       Date:  2012-04       Impact factor: 3.352

2.  Complications from injectable materials used for breast augmentation.

Authors:  Walter Peters; Victor Fornasier
Journal:  Can J Plast Surg       Date:  2009

3.  Treatment for displacement of PAAG mixture after injection augmentation mammoplasty.

Authors:  Liang Chen; Liu Sha; Shu-Peng Huang; Shi-Rong Li; Zhen-Xiang Wang
Journal:  Int J Clin Exp Med       Date:  2015-03-15

4.  Complications and management of breast enhancement using hyaluronic acid.

Authors:  Hidenori Ishii; Kazuaki Sakata
Journal:  Plast Surg (Oakv)       Date:  2014       Impact factor: 0.947

5.  Application of Periareolar Mammaplasty with the Tissue Folding Technique in Breast Reshaping following Polyacrylamide Hydrogel Removal.

Authors:  Yantao Cai; Bin Liu; Mingjuan Liao; Liu He; Chenfang Zhu
Journal:  Breast Care (Basel)       Date:  2019-06-11       Impact factor: 2.860

Review 6.  Imaging Spectrum of Augmented Breast and Post-Mastectomy Reconstructed Breast with Common Complications: A Pictorial Essay.

Authors:  Renuka Nair Kunju Krisnan; Niketa Chotai
Journal:  Korean J Radiol       Date:  2021-04-09       Impact factor: 3.500

7.  Polyacrylamide hydrogel injection for breast augmentation: another injectable failure.

Authors:  Zhenxiang Wang; Shirong Li; Lingli Wang; Shu Zhang; Yan Jiang; Jinping Chen; Donglin Luo
Journal:  Med Sci Monit       Date:  2012-06

8.  Management of complication after breast augmentation with methacrylate.

Authors:  Roberto Grella; Aurora Almadori; Antonio D'Ari; Vincenza Romanucci; Francesco D'Andrea
Journal:  Int J Surg Case Rep       Date:  2015-07-10

9.  Clinicopathological Analysis of 90 Cases of Polyacrylamide Hydrogel Injection for Breast Augmentation Including 2 Cases Followed by Breast Cancer.

Authors:  Ying Yang; Shumo Li; Jia He; Xian Zhao; Wei Chen; Xiaoming Dai; Liu Liu
Journal:  Breast Care (Basel)       Date:  2019-05-29       Impact factor: 2.860

Review 10.  Late-onset inflammatory adverse reactions related to soft tissue filler injections.

Authors:  Jaume Alijotas-Reig; Maria Teresa Fernández-Figueras; Lluís Puig
Journal:  Clin Rev Allergy Immunol       Date:  2013-08       Impact factor: 10.817

View more