Literature DB >> 12431150

Endotension distribution and the role of thrombus following endovascular AAA exclusion.

John P Pacanowski1, Scott L Stevens, Michael B Freeman, Robert S Dieter, Lance A Klosterman, Stacy S Kirkpatrick, John W Ragsdale, S Elizabeth Davis, Mitchell H Goldman.   

Abstract

PURPOSE: To determine the pattern of strain and pressure transmitted to an aortic aneurysm wall before and after endovascular exclusion and to evaluate the role of sac thrombus on the conduction of pressure and wall strain.
METHODS: Three canine thoracic aortas were used to create abdominal aortic aneurysms (AAA). The segments were placed on a pulsatile pump system, and 8 strain transducers were positioned in the aneurysm sac. Baseline strain/pressure (S/P) was recorded in 1 animal, then the AAA was excluded with a stent-graft. Thrombin was injected into the sac, and strain/pressure was recorded at 7 systemic pressures (35 to 120 mmHg) over 6 hours. The thrombus was replaced with fibrin glue, and S/P was recorded over 4 hours. Additional trials using whole and 50% diluted unclotted blood were performed prior to sac thrombosis. Computed tomography and angiography were performed before and after aneurysm exclusion.
RESULTS: Pressure transmitted to the aneurysm wall decreased following stent-graft placement (p<or=0.001). Strain/pressure was not distributed evenly in the sac (p<or=0.05), and varying systemic pressures did not affect this distribution. Pressures near the stent-graft were higher than those laterally (p<or=0.001) in all trials with interposed fresh thrombus and fibrin thrombus. The fibrin group had elevated baseline measurements, but correction for the elevated values did not influence the statistical significance (p<or=0.001). Blood and fibrin thrombus reduced transmitted wall pressure to a similar degree. Overall S/P in the fluid-filled nonclotted sac was significantly lower (p<or=0.001) than in the thrombus groups.
CONCLUSIONS: Endovascular AAA exclusion reduced strain and pressure conducted to the aneurysm wall, and the distribution of transmitted pressure in the excluded sac without endoleak differed regardless of the sac contents. Fresh thrombus reduced transmittedS/P in all trials at all systemic pressures, as did fibrin thrombus but in a less predictable fashion.

Entities:  

Mesh:

Year:  2002        PMID: 12431150     DOI: 10.1177/152660280200900516

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

1.  Significance of initial aortic aneurysm pressure sensor readings varies with aortic endograft design.

Authors:  Gautam Shrikhande; Sikandar Khan; Hafiz Hussain; Alicia Menezes; James McKinsey; Harry Bush
Journal:  World J Surg       Date:  2010-12       Impact factor: 3.352

2.  Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up.

Authors:  Hanno Hoppe; Jocelyn A Segall; Timothy K Liem; Gregory J Landry; John A Kaufman
Journal:  Eur Radiol       Date:  2007-12-20       Impact factor: 5.315

3.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.

Authors:  Fabian Springer; Roland Schlierf; Joachim-Georg Pfeffer; Andreas H Mahnken; Uwe Schnakenberg; Thomas Schmitz-Rode
Journal:  Eur Radiol       Date:  2007-03-06       Impact factor: 7.034

  3 in total