Literature DB >> 12430033

[Two years experience with the new accommodative 1 CU intraocular lens].

M Küchle1, N X Nguyen, A Langenbucher, G C Gusek-Schneider, B Seitz.   

Abstract

After marked improvement of optical rehabilitation of cataract patients during the last decades due to small incision surgery and foldable intraocular lenses (IOL), presbyopia is now one of the great unsolved questions in ophthalmology. During recent years a new accommodative IOL, the 1CU lens, has been developed based on the concepts of K.D. Hanna and on finite element computer simulation models. The 1CU IOL is designed to transform contracting forces of the ciliary muscle into anterior movement of the IOL optic (optic-shift concept). After the first implantation of a 1CU IOL in Erlangen in June 2000, we have now successfully implanted the 1CU IOL in over 90 patients. Our experiences and the results of several clinical studies indicate good and safe implantability, good centration, no IOL-specific complications, and good distance visual acuity. In comparison to control groups with conventional IOL, patients with the 1CU enjoyed significantly better distance-corrected near visual acuity, a larger accommodative range, and increased anterior and posterior axial movement of the lens optic after medical stimulation or inhibition of the ciliary muscle. We interpret our results as confirmation of the optic-shift concept of the 1CU IOL. Overall, the concept of accommodative IOL appears attractive and may have a great potential in the future. Additional studies including randomized blind multicenter evaluation of the 1CU IOL are necessary to further evaluate long-term and accommodative results.

Entities:  

Mesh:

Year:  2002        PMID: 12430033     DOI: 10.1007/s00347-002-0721-y

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  6 in total

1.  [Accommodation ability under the aspect of refractive, demographic, and biometric parameters].

Authors:  K Klatt; A Langenbucher; B Seitz; N X Nguyen
Journal:  Ophthalmologe       Date:  2006-12       Impact factor: 1.059

2.  Biomechanical analysis of the accommodative apparatus in primates.

Authors:  Klaus Ehrmann; Arthur Ho; Jean-Marie Parel
Journal:  Clin Exp Optom       Date:  2008-02-15       Impact factor: 2.742

3.  Accommodation after Nd: YAG capsulotomy in patients with accommodative posterior chamber lens 1CU.

Authors:  Nhung X Nguyen; B Seitz; S Reese; A Langenbucher; M Küchle
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-14       Impact factor: 3.117

4.  Functionalised polysiloxanes as injectable, in situ curable accommodating intraocular lenses.

Authors:  Xiaojuan Hao; Justine L Jeffery; John S Wilkie; Gordon F Meijs; Anthony B Clayton; Jason D Watling; Arthur Ho; Viviana Fernandez; Carolina Acosta; Hideo Yamamoto; Mohamed G M Aly; Jean-Marie Parel; Timothy C Hughes
Journal:  Biomaterials       Date:  2010-08-07       Impact factor: 12.479

5.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

6.  [Measurement of accommodation using optical biometry].

Authors:  A Nurispahic; K Kotliar; I Lanzl
Journal:  Ophthalmologe       Date:  2008-04       Impact factor: 1.059

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.