Literature DB >> 12426498

Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.

Rafael Leonardo Xediek Consani1, Saide Sarckis Domitti, Simonides Consani.   

Abstract

STATEMENT OF PROBLEM: The pressure of final closure may be released when the flask is removed from the mechanical or pneumatic press and placed in the spring clamp. This release in pressure may result in dimensional changes that distort the denture base.
PURPOSE: The purpose of this study was to investigate differences between the dimensional stability of standardized simulated denture bases processed by traditional moist heat-polymerization and those processed by use of a new tension system.
MATERIAL AND METHODS: A metal master die was fabricated to simulate an edentulous maxillary arch without irregularities in the alveolar ridge walls. A silicone mold of this metallic die was prepared, and 40 stone casts were formed from the mold with type III dental stone. The casts were randomly assigned to 4 test groups (A-D) of 10 specimens each. A uniform denture base pattern was made on each stone cast with a 1.5-mm thickness of base-plate wax, measured with a caliper. The patterns were invested for traditional hot water processing. A polymethyl methacrylate dough was prepared and packed for processing. The flasks in groups A and B were closed with the traditional pressure technique and placed in spring clamps after final closure. The flasks in groups C and D were pressed between the metallic plates of the new tension system after the final closure. The group A and C flasks were immediately immersed in the water processing unit at room temperature (25 degrees +/- 2 degrees C). The unit was programmed to raise the temperature to 74 degrees C over 1 hour, and then maintained the temperature at 74 degrees C for 8 hours. The group B and D flasks were bench stored at room temperature (25 degrees +/- 2 degrees C) for 6 hours and were then subjected to the same moist heat polymerization conditions as groups A and C. All processed dentures were bench cooled for 3 hours. After recovery from the flasks, the base-cast sets were transversally sectioned into 3 parts (corresponding to 3 zones): (1) distal of the canines, (2) mesial of the first molars, and (3) mesial of the posterior palate). These areas had been previously established and standardized by use of a pattern denture in the sawing device to determine the sections in each base-cast set. Base-cast gaps were measured at 5 predetermined points on each section with an optical micrometer that had a tolerance of 0.001 mm. Collected data were analyzed with analysis of variance and Tukey's test.
RESULTS: Denture bases processed with the new tension system exhibited significantly better base adaptation than those processed with traditional acrylic resin packing. Immediately after polymerization (Groups A and C), mean dimensional change values were 0.213 +/- 0.055 mm for the traditional packing technique and 0.173 +/- 0.050 mm for new tension system. After delayed polymerization (Groups B and D), the values were 0.216 +/- 0.074 mm for the traditional packing technique and 0.164 +/- 0.032 mm for new tension system. With both techniques, dimensional changes in the posterior palatal zone were greater (conventional = 0.286 +/- 0.038 mm; new system = 0.214 +/- 0.024 mm) than those elsewhere on the base-cast set.
CONCLUSION: Within the limitations of this study, the new tension packing system was associated with decreased dimensional changes in the simulated maxillary denture bases processed with heat-polymerization.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12426498     DOI: 10.1067/mpr.2002.128447

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  A comparative evaluation of the dimensional accuracy of heat polymerised PMMA denture base cured by different curing cycles and clamped by R S technique and conventional method - An In-vitro study.

Authors:  Mandava Ramesh Babu; C Satyanageswar Rao; Syed Tauqheer Ahmed; J S V Bharat; N Venugopal Rao; V Vinod
Journal:  J Int Oral Health       Date:  2014-04-26

3.  Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins.

Authors:  Ghazal Savabi; Omid Savabi; Badrosadat Dastgheib; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

4.  Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation.

Authors:  Rafael L X Consani; Rose Y Iwasaki; Marcelo F Mesquita; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-04-29

5.  Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth.

Authors:  Wagner A Negreiros; Rafael L X Consani; Marcelo F Mesquita; Mario A C Sinhoreti; Ivan R Faria
Journal:  Open Dent J       Date:  2009-03-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.