Literature DB >> 12415886

Indoor air quality assessment of daycare facilities with carbon dioxide, temperature, and humidity as indicators.

Shiaw-Fen Ferng1, Li-Wen Lee.   

Abstract

Poor indoor air quality (IAQ) in daycare facilities affects both attending children and care providers. Incident rates of upper-respiratory-tract infections have been reported to be higher in children who attend daycare. Excessive carbon dioxide (CO2) exposure can cause several health effects and even sudden infant death. For this study, 26 facilities were randomly selected in a Midwestern county of the United States. CO2, room temperature, and relative humidity were used as indicators for IAQ and comfort levels. These IAQ parameters were continuously monitored for eight hours at each facility by a direct-reading instrument that was calibrated before each measurement. More than 50 percent of the facilities had an average CO2 level over the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) standard of 1,000 parts per million (ppm). For temperature and relative humidity, respectively, 42.3 percent and 15.4 percent of facilities were outside of the ASHRAE-recommended comfort zones. The nap-time average CO2 level was about 117 ppm higher than the non-nap-time level. The increment of the nap-time CO2 level in the sleeping-only room over the level in multipurpose rooms was statistically significant (p < .05). According to stepwise multiple regression analysis, nap-time CO2 level was predicted by CO2 level before occupancy, nap-time average temperature, carbon monoxide, and child density (R2 = .83). It is recommended that an appropriate IAQ standard for daycare facilities be established and that children should not be placed in a completely isolated room during nap time.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12415886

Source DB:  PubMed          Journal:  J Environ Health        ISSN: 0022-0892            Impact factor:   1.179


  10 in total

1.  Association between barracks type and acute respiratory infection in a gender integrated Army basic combat training population.

Authors:  Duvel W White; Charles E Feigley; Robert E McKeown; Joseph J Hout; James R Hebert
Journal:  Mil Med       Date:  2011-08       Impact factor: 1.437

2.  Fungal DNA in dust in Swedish day care centres: associations with respiratory symptoms, fractional exhaled nitrogen oxide (FeNO) and C-reactive protein (CRP) in serum among day care centre staff.

Authors:  Dan Norbäck; Gui-Hong Cai; Ivan Kreft; Erik Lampa; Gunilla Wieslander
Journal:  Int Arch Occup Environ Health       Date:  2015-07-17       Impact factor: 3.015

3.  CO(2) concentration in day care centres is related to wheezing in attending children.

Authors:  Pedro Carreiro-Martins; João Viegas; Ana Luisa Papoila; Daniel Aelenei; Iolanda Caires; José Araújo-Martins; João Gaspar-Marques; Maria Manuela Cano; Ana Sofia Mendes; Daniel Virella; José Rosado-Pinto; Paula Leiria-Pinto; Isabella Annesi-Maesano; Nuno Neuparth
Journal:  Eur J Pediatr       Date:  2014-03-04       Impact factor: 3.183

4.  Multiple traumatic insemination events reduce the ability of bed bug females to maintain water balance.

Authors:  Joshua B Benoit; Andrew J Jajack; Jay A Yoder
Journal:  J Comp Physiol B       Date:  2011-08-20       Impact factor: 2.200

5.  Indoor air quality assessment in child care and medical facilities in Korea.

Authors:  Ehsanul Kabir; K-H Kim; Jong Ryeul Sohn; Bo Youn Kweon; Jong Hyun Shin
Journal:  Environ Monit Assess       Date:  2011-11-16       Impact factor: 2.513

6.  Addition of alarm pheromone components improves the effectiveness of desiccant dusts against Cimex lectularius.

Authors:  Joshua B Benoit; Seth A Phillips; Travis J Croxall; Brady S Christensen; Jay A Yoder; David L Denlinger
Journal:  J Med Entomol       Date:  2009-05       Impact factor: 2.278

7.  Indoor air quality and thermal comfort-results of a pilot study in elderly care centers in Portugal.

Authors:  Ana Mendes; Cristiana Pereira; Diana Mendes; Lívia Aguiar; Paula Neves; Susana Silva; Stuart Batterman; João Paulo Teixeira
Journal:  J Toxicol Environ Health A       Date:  2013

8.  Assessment of indoor air pollution in homes with infants.

Authors:  Anna Ruth Pickett; Michelle L Bell
Journal:  Int J Environ Res Public Health       Date:  2011-12-05       Impact factor: 3.390

9.  A novel solid state non-dispersive infrared CO2 gas sensor compatible with wireless and portable deployment.

Authors:  Desmond Gibson; Calum MacGregor
Journal:  Sensors (Basel)       Date:  2013-05-29       Impact factor: 3.576

10.  The Relative Performance of NDIR-based Sensors in the Near Real-time Analysis of CO₂ in Air.

Authors:  Sudhir Kumar Pandey; Ki-Hyun Kim
Journal:  Sensors (Basel)       Date:  2007-09-03       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.