Literature DB >> 12413221

Composite restorations: influence of flowable and self-curing resin composite linings on microleakage in vitro.

Anne Peutzfeldt1, Erik Asmussen.   

Abstract

This in vitro study evaluated the microleakage at enamel (occlusal) and dentin (gingival) margins of MOD resin composite restorations made with different incremental insertion techniques. MOD cavities were prepared on 60 extracted human molars with the proximal margins placed 1 mm below the cemento-enamel junction. All teeth were acid-etched and treated with One-Step adhesive, then restored with a hybrid resin composite (Renew) with and without a flowable composite (AEliteflo) or a self-curing composite (Bisfil 2B) as the first increment in the proximal boxes. The time of placement of the second increment in relation to curing of the first increment was also varied. After polishing, the teeth were soaked in 0.5% basic fuchsin for 24 hours, sectioned and evaluated for dye penetration. None of the restorative techniques prevented microleakage at the enamel and dentin margins. However, microleakage at dentin margins were significantly reduced by the use of a flowable composite as the first increment in the proximal boxes. Time of placement in relation to curing had no influence on microleakage. Microleakage was lower at enamel margins than at dentin margins; however, besides microleakage at the enamel-restoration interface, 37 of the 60 restored teeth (62%) displayed at least one white line in enamel adjacent to the composite restoration.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12413221

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  7 in total

1.  In vivo interfacial adaptation of class II resin composite restorations with and without a flowable resin composite liner.

Authors:  Anders Lindberg; J W V van Dijken; P Hörstedt
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

2.  In vitro evaluation of marginal and internal adaptation of class II CAD/CAM ceramic restorations with different resinous bases and interface treatments.

Authors:  María José Sandoval; Giovanni Tommaso Rocca; Ivo Krejci; Michael Mandikos; Didier Dietschi
Journal:  Clin Oral Investig       Date:  2015-04-16       Impact factor: 3.573

3.  Microleakage in Class V cavities with self-etching adhesive system and conventional rotatory or laser Er,Cr:YSGG.

Authors:  K Trelles; J Arnabat; T España-Tost
Journal:  Laser Ther       Date:  2012-12-26

4.  Evaluating the Marginal Integrity of Bulk Fill Fibre Reinforced Composites in Bio-mimetically Restored Tooth.

Authors:  Arun Kumar Patnana; V Narsimha Rao Vanga; Srinivas Kumar Chandrabhatla
Journal:  J Clin Diagn Res       Date:  2017-06-01

5.  Clinical performance of a nanofilled resin composite with and without an intermediary layer of flowable composite: a 2-year evaluation.

Authors:  Sebastian Stefanski; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2010-11-23       Impact factor: 3.573

6.  Retrospective evaluation of the clinical performance of direct composite restorations using the snow-plow technique: Up to 4 years follow-up.

Authors:  Ailreza Borouziniat; Hossain Khaki; Sara Majidinia
Journal:  J Clin Exp Dent       Date:  2019-11-01

7.  Marginal sealing ability of silorane and methacrylate resin composites in class II cavities: A scanning electron microscopic study.

Authors:  Jyothi Kashi Nanjundasetty; Soumyaranjan Nanda; Venugopal Panuganti; Jayashankar Chatra Marigowda
Journal:  J Conserv Dent       Date:  2013-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.