Literature DB >> 12412654

Full-field optical coherence tomography with thermal light.

Blandine Laude1, Antonello De Martino, Bernard Drévillon, Laurence Benattar, Laurent Schwartz.   

Abstract

A simple optical coherence tomography system has been developed based on a white-light Linnik interferometric microscope with its reference mirror mounted on a piezoelectric translator. The geometrical extension of the optics allows efficient illumination of this device with a low-power (3-W) light bulb, yielding full-field interferometric images at 50 Hz with a fast CCD camera. Owing to the very broad spectral width of the light source and of the camera response, we achieved axial resolutions equal to 1.1 microm in free space and 0.7 microm through a standard microscope cover plate. Tomographic images of an epithelial cell smear and of an hematological sample are shown.

Mesh:

Year:  2002        PMID: 12412654     DOI: 10.1364/ao.41.006637

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  6 in total

1.  Partially coherent illumination in full-field interferometric synthetic aperture microscopy.

Authors:  Daniel L Marks; Brynmor J Davis; Stephen A Boppart; P Scott Carney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-02       Impact factor: 2.129

2.  Multifrequency-swept optical coherence microscopy for highspeed full-field tomographic vibrometry in biological tissues.

Authors:  Samuel Choi; Keita Sato; Takeru Ota; Fumiaki Nin; Shogo Muramatsu; Hiroshi Hibino
Journal:  Biomed Opt Express       Date:  2017-01-06       Impact factor: 3.732

3.  Compound prism design principles, III: linear-in-wavenumber and optical coherence tomography prisms.

Authors:  Nathan Hagen; Tomasz S Tkaczyk
Journal:  Appl Opt       Date:  2011-09-01       Impact factor: 1.980

4.  Interferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy.

Authors:  Brynmor J Davis; Daniel L Marks; Tyler S Ralston; P Scott Carney; Stephen A Boppart
Journal:  Sensors (Basel)       Date:  2008-06-01       Impact factor: 3.576

5.  Simultaneous optical mapping of intracellular free calcium and action potentials from Langendorff perfused hearts.

Authors:  Guy Salama; Seong-min Hwang
Journal:  Curr Protoc Cytom       Date:  2009-07

6.  High-throughput spatial sensitive quantitative phase microscopy using low spatial and high temporal coherent illumination.

Authors:  Azeem Ahmad; Vishesh Dubey; Nikhil Jayakumar; Anowarul Habib; Ankit Butola; Mona Nystad; Ganesh Acharya; Purusotam Basnet; Dalip Singh Mehta; Balpreet Singh Ahluwalia
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.