Literature DB >> 12412025

Magnetic resonance safety update 2002: implants and devices.

Frank G Shellock1.   

Abstract

The preservation of a safe magnetic resonance (MR) environment requires constant vigilance by MR healthcare professionals, particularly with regard to the management of patients with metallic biomedical implants or devices. The variety and complexity of implants and devices constantly changes, requiring continuous attention and diligence with regard to obtaining the most current and accurate information about these objects relative to the MR environment. This review article discusses MR safety and MR compatibility issues and presents important information for a variety of implants and devices, with an emphasis on those objects that have recently undergone evaluation or that require additional consideration because of existing controversy or confusion. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12412025     DOI: 10.1002/jmri.10196

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  40 in total

1.  RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.

Authors:  Fabio Settecase; Steven W Hetts; Alastair J Martin; Timothy P L Roberts; Anthony F Bernhardt; Lee Evans; Vincent Malba; Maythem Saeed; Ronald L Arenson; Walter Kucharzyk; Mark W Wilson
Journal:  Acad Radiol       Date:  2010-11-13       Impact factor: 3.173

2.  Steerable catheter microcoils for interventional MRI reducing resistive heating.

Authors:  Anthony Bernhardt; Mark W Wilson; Fabio Settecase; Leland Evans; Vincent Malba; Alastair J Martin; Maythem Saeed; Timothy P L Roberts; Ronald L Arenson; Steven W Hetts
Journal:  Acad Radiol       Date:  2010-11-13       Impact factor: 3.173

Review 3.  Magnetic resonance imaging of patients with airway stents.

Authors:  Yang Xia; Rui Jin; Wen Li; Huahao Shen
Journal:  J Thorac Dis       Date:  2018-10       Impact factor: 2.895

4.  Transcatheter closure of atrial septal defects improves right ventricular volume, mass, function, pulmonary pressure, and functional class: a magnetic resonance imaging study.

Authors:  S P Schoen; T Kittner; S Bohl; M U Braun; G Simonis; A Schmeisser; R H Strasser
Journal:  Heart       Date:  2005-11-11       Impact factor: 5.994

5.  Safety of cardiovascular magnetic resonance in patients with cardiovascular implants and devices.

Authors:  S K Prasad; D J Pennell
Journal:  Heart       Date:  2004-11       Impact factor: 5.994

6.  MAPS - a Magic Angle Positioning System for Enhanced Imaging in High-Field Small-Bore MRI.

Authors:  Alexander Squires; Kevin C Chan; Leon C Ho; Ian A Sigal; Ning-Jiun Jan; Zion Tsz Ho Tse
Journal:  J Med Robot Res       Date:  2016-03-31

7.  Contrast-enhanced cardiovascular magnetic resonance in the hyperacute phase of ST-elevation myocardial infarction.

Authors:  Eric Larose; Julie Côté; Josep Rodés-Cabau; Bernard Noël; Gerald Barbeau; Edith Bordeleau; Santiago Miró; Bernard Brochu; Robert Delarochellière; Olivier F Bertrand
Journal:  Int J Cardiovasc Imaging       Date:  2009-03-15       Impact factor: 2.357

Review 8.  MRI-related heating near deep brain stimulation electrodes: more data are needed.

Authors:  Akshay A Gupte; Devashish Shrivastava; Maggie A Spaniol; Aviva Abosch
Journal:  Stereotact Funct Neurosurg       Date:  2011-04-13       Impact factor: 1.875

Review 9.  Biological effects and safety in magnetic resonance imaging: a review.

Authors:  Valentina Hartwig; Giulio Giovannetti; Nicola Vanello; Massimo Lombardi; Luigi Landini; Silvana Simi
Journal:  Int J Environ Res Public Health       Date:  2009-06-10       Impact factor: 3.390

Review 10.  Physiological recordings: basic concepts and implementation during functional magnetic resonance imaging.

Authors:  Marcus A Gray; Ludovico Minati; Neil A Harrison; Peter J Gianaros; Vitaly Napadow; Hugo D Critchley
Journal:  Neuroimage       Date:  2009-05-19       Impact factor: 6.556