Comprehensive assessment of patent ductus arteriosus by echocardiography before transcatheter closure.

Claudio Ramaciotti1, Matthew S Lemler, Lindy Moake, Thomas M Zellers.   

Abstract

BACKGROUND: Anatomic type and angiographic measurements of patent ductus arteriosus (PDA) are used to determine the suitability of transcatheter closure (TCC). The purpose of this study is to evaluate whether these PDA features can be obtained by 2-dimensional echocardiography (2DE).
METHODS: We retrospectively compared PDA measurements and type from 36 patients submitted to TCC between November 1995 and October 2000.
RESULTS: The patient age ranged between 2 months to 10.5 years (median = 1.2 years). A significant correlation was found between measurements of PDA minimal diameter (R(2) = 0.88) and diameter at aortic ostium (R(2) = 0.72); whereas a poor correlation existed between measurements of the ampulla length. The 2DE and angiographic PDA classification were concordant in 31 of 36 (86%) patients.
CONCLUSION: Our data support the use of 2DE measurements of PDA minimal diameter and PDA diameter at the aortic end to assess suitability for TCC. In the majority of cases, PDA type can be diagnosed by 2DE.

Entities:  

Mesh:

Year:  2002        PMID: 12411898     DOI: 10.1067/mje.2002.124573

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Echocardiographic Versus Angiographic Assessment of Patent Arterial Duct in Percutaneous Closure: Towards X-ray Free Duct Occlusion?

Authors:  Inês Carmo Mendes; Hannah Heard; Kelly Peacock; Thomas Krasemann; Gareth J Morgan
Journal:  Pediatr Cardiol       Date:  2017-01-11       Impact factor: 1.655

2.  Outcomes of Early Ligation of Patent Ductus Arteriosus in Preterms, Multicenter Experience.

Authors:  Mohamed H Ibrahim; Ahmed A Azab; Naglaa M Kamal; Mostafa A Salama; Hatem H Elshorbagy; Enas A A Abdallah; Abdulrahman Hammad; Laila M Sherief
Journal:  Medicine (Baltimore)       Date:  2015-06       Impact factor: 1.889

3.  Accuracy of Routine 2D Echocardiography to Estimate Patent Ductus Arteriosus Type and Dimension and Predict Device Selection for Successful PDA Occlusion.

Authors:  Mohammed Omar Galal; Zaheer Ahmad; Arif Hussain; Masroor Sharfi; Yahia El Mahdi; Fayzah El Khattab; Amjad Alkouatli; Riad Abou Zahr
Journal:  J Saudi Heart Assoc       Date:  2021-11-29

4.  Transcatheter closure of patent ductus arteriosus: initial study on echocardiographic estimation of device size.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Seyed Ebrahim Kassaian; Ebrahim Nematipour
Journal:  J Tehran Heart Cent       Date:  2010-09-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.