[Visual acuity measured via the Freiburg visual acuity test (FVT), Bailey Lovie chart and Landolt Ring chart].

Wolfgang Wesemann1.   

Abstract

INTRODUCTION: If different ways for correcting refractive errors of the human eye have to be compared, accurate and reproducible measurement procedures are necessary.
METHODS: Binocular visual acuity of 130 students without pathologies was measured with the Freiburg Visual Acuity Test, the Bailey-Lovie chart and a Landolt ring chart (4 orientations). The reproducibility of the FVT was determined by repeated measurements.
RESULTS: The average visual acuity was 1.93 +/- 0.03 (= 20/10.4) with the FVT, 1.82 +/- 0.03 (= 20/11) with the Landolt ring chart, and 1.48 +/- 0.02 (= 20/13.5) with the Bailey-Lovie chart. 50 % of all repeated measurements with the FVT were within an interval of +/- 0.035 logMAR from the mean value. 95 % were within +/- 0.1 logMAR. Results of earlier studies are discussed.
CONCLUSION: On average, visual acuity values found with the Freiburg Visual Acuity Test were slightly larger as compared to the Landolt ring chart (difference = 0.025 logMAR). Taking the maximal difference of 0.05 logMAR tolerated by the international standard DIN EN ISO 8597 into account, both tests are equivalent. The results found with the Bailey-Lovie chart were substantially lower as compared to the Landolt ring chart (difference = 0.09 logMAR). The Freiburg Visual Acuity Test has a high reproducibility and measures visual acuity on a continuous scale that is not limited to the traditional visual acuity steps. Thus, it can be recommended as a reference procedure for comparative visual acuity studies.

Entities:  

Mesh:

Year:  2002        PMID: 12410466     DOI: 10.1055/s-2002-35168

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  21 in total

1.  Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability.

Authors:  Eva Stifter; Franz König; Thomas Lang; Peter Bauer; Sibylla Richter-Müksch; Michaela Velikay-Parel; Wolfgang Radner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-12-10       Impact factor: 3.117

2.  Visual acuity testing in diabetic subjects: the decimal progression chart versus the Freiburg visual acuity test.

Authors:  Lars Loumann Knudsen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

Review 3.  [Current state of wavefront guided corneal surgery to correct refraction disorders].

Authors:  T Kohnen; J Bühren
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

4.  Different effect of dioptric defocus vs. light scatter on the pattern electroretinogram (PERG).

Authors:  Michael Bach; Marcel Mathieu
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

5.  [Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS). A new test to determine contrast sensitivity under variable ambient and glare luminance levels].

Authors:  E Terzi; J Bühren; W Wesemann; T Kohnen
Journal:  Ophthalmologe       Date:  2005-05       Impact factor: 1.059

6.  Visual acuity and X-linked color blindness.

Authors:  Herbert Jägle; Emanuela de Luca; Ludwig Serey; Michael Bach; Lindsay T Sharpe
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-23       Impact factor: 3.117

Review 7.  [Optical quality after refractive corneal surgery].

Authors:  T Kohnen; J Bühren; M Cichocki; T Kasper; E Terzi; C Ohrloff
Journal:  Ophthalmologe       Date:  2006-03       Impact factor: 1.059

8.  Resolving the clinical acuity categories "hand motion" and "counting fingers" using the Freiburg Visual Acuity Test (FrACT).

Authors:  C Lange; N Feltgen; B Junker; K Schulze-Bonsel; M Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-03       Impact factor: 3.117

9.  Objective assessment of visual acuity: a refined model for analyzing the sweep VEP.

Authors:  Torsten Strasser; Fadi Nasser; Hana Langrová; Ditta Zobor; Łukasz Lisowski; Dominic Hillerkuss; Carla Sailer; Anne Kurtenbach; Eberhart Zrenner
Journal:  Doc Ophthalmol       Date:  2019-01-29       Impact factor: 2.379

10.  A comparison of the performance of three visual evoked potential-based methods to estimate visual acuity.

Authors:  Anne Kurtenbach; Hana Langrová; Andre Messias; Eberhart Zrenner; Herbert Jägle
Journal:  Doc Ophthalmol       Date:  2012-11-11       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.