Literature DB >> 12409574

CT tumor measurement for therapeutic response assessment: comparison of unidimensional, bidimensional, and volumetric techniques initial observations.

Srinivasa R Prasad1, Kartik S Jhaveri, Sanjay Saini, Peter F Hahn, Elkan F Halpern, James E Sumner.   

Abstract

PURPOSE: To compare unidimensional, bidimensional, and volumetric techniques for evaluation of treatment response in patients with liver metastases from breast cancer in a phase III clinical trial.
MATERIALS AND METHODS: Helical computed tomographic (CT) studies in 38 patients with liver metastases from breast cancer who were enrolled in a phase III clinical trial were evaluated before treatment and at 6 months after treatment. Two subspecialty radiologists measured all lesions on transverse CT scans with use of electronic calipers according to both unidimensional and bidimensional criteria. Volumetric measurements were made by tracing individual lesions. Measurements of individual lesions were summed to obtain patient response, which was categorized as complete response, disappearance of lesions; partial response, greater than 30% decrease in tumor diameter (unidimensional), greater than 50% reduction in tumor area (bidimensional), or greater than 65% reduction in tumor volume (volumetric); disease progression, greater than 20% increase in tumor diameter, greater than 25% increase in tumor area, or greater than 73% increase in tumor volume: or stable disease (size response other than that of complete response, partial response, or disease progression).
RESULTS: In 37 patients, there was concordant treatment response with use of unidimensional and bidimensional techniques. Volumetric measurement produced results different from those of the unidimensional and bidimensional techniques in 12 and 13 patients, respectively. In six patients with partial response per unidimensional and bidimensional criteria, the response based on the volumetric technique was stable disease. In two patients with stable disease per bidimensional and unidimensional criteria, the response was partial response by volumetric measurement. In four patients with disease progression per bidimensional and unidimensional criteria, the response was stable disease per volumetric criteria.
CONCLUSION: Volumetric measurement of tumor burden gives different results for treatment response compared with that of the unidimensional or bidimensional technique in a considerable proportion of patients. Copyright RSNA, 2002

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12409574     DOI: 10.1148/radiol.2252011604

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  73 in total

1.  Adrenal gland volume measurement in septic shock and control patients: a pilot study.

Authors:  Stephanie Nougaret; B Jung; S Aufort; G Chanques; S Jaber; B Gallix
Journal:  Eur Radiol       Date:  2010-06-04       Impact factor: 5.315

2.  Diffusion-Weighted Imaging for Predicting and Monitoring Primary Central Nervous System Lymphoma Treatment Response.

Authors:  W-Y Huang; J-B Wen; G Wu; B Yin; J-J Li; D-Y Geng
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

Review 3.  Computerized PET/CT image analysis in the evaluation of tumour response to therapy.

Authors:  W Lu; J Wang; H H Zhang
Journal:  Br J Radiol       Date:  2015-02-27       Impact factor: 3.039

4.  Multimodal imaging and computer assisted diagnosis for functional tumour characterisation.

Authors:  Hans-Ulrich Kauczor
Journal:  Cancer Imaging       Date:  2005-06-21       Impact factor: 3.909

5.  Automated measurement of lymph nodes: a phantom study.

Authors:  Sebastian Keil; Cedric Plumhans; Florian F Behrendt; Sven Stanzel; Michael Suehling; Georg Mühlenbruch; Andreas H Mahnken; Rolf W Günther; Marco Das
Journal:  Eur Radiol       Date:  2008-12-24       Impact factor: 5.315

Review 6.  [Volumetry of metastases from renal cell carcinoma: comparison with the RECIST criteria].

Authors:  A Graser; C R Becker; M F Reiser; C Stief; M Staehler
Journal:  Radiologe       Date:  2008-09       Impact factor: 0.635

7.  Radiologic-pathologic analysis of contrast-enhanced and diffusion-weighted MR imaging in patients with HCC after TACE: diagnostic accuracy of 3D quantitative image analysis.

Authors:  Julius Chapiro; Laura D Wood; MingDe Lin; Rafael Duran; Toby Cornish; David Lesage; Vivek Charu; Rüdiger Schernthaner; Zhijun Wang; Vania Tacher; Lynn Jeanette Savic; Ihab R Kamel; Jean-François Geschwind
Journal:  Radiology       Date:  2014-07-15       Impact factor: 11.105

8.  Treatment response classification of liver metastatic disease evaluated on imaging. Are RECIST unidimensional measurements accurate?

Authors:  Michael Mantatzis; Stylianos Kakolyris; Kyriakos Amarantidis; Anastasios Karayiannakis; Panos Prassopoulos
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

9.  Semiautomatic volumetric tumor segmentation for hepatocellular carcinoma: comparison between C-arm cone beam computed tomography and MRI.

Authors:  Vania Tacher; MingDe Lin; Michael Chao; Lars Gjesteby; Nikhil Bhagat; Abdelkader Mahammedi; Roberto Ardon; Benoit Mory; Jean-François Geschwind
Journal:  Acad Radiol       Date:  2013-04       Impact factor: 3.173

Review 10.  Volumetric analysis at abdominal CT: oncologic and non-oncologic applications.

Authors:  Virginia B Planz; Meghan G Lubner; Perry J Pickhardt
Journal:  Br J Radiol       Date:  2018-11-30       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.