Literature DB >> 12405594

Linear poroelastic cancellous bone anisotropy: trabecular solid elastic and fluid transport properties.

Sean S Kohles1, Julie B Roberts.   

Abstract

The mechanical performance of cancellous bone is characterized using experiments which apply linear poroelasticity theory. It is hypothesized that the anisotropic organization of the solid and pore volumes of cancellous bone can be physically characterized separately (no deformable boundary interactive effects) within the same bone sample. Due to its spongy construction, the in vivo mechanical function of cancellous or trabecular bone is dependent upon fluid and solid materials which may interact in a hydraulic, convective fashion during functional loading. This project provides insight into the organization of the tissue, ie., the trabecular connectivity, by defining the separate nature of this biphasic performance. Previous fluid flow experiments [Kohles et al., 2001, Journal of Biomechanics, 34(11), pp. 1197-1202] describe the pore space via orthotropic permeability. Ultrasonic wave propagation through the trabecular network is used to describe the solid component via orthotropic elastic moduli and material stiffness coefficients. The linear poroelastic nature of the tissue is further described by relating transport (fluid flow) and elasticity (trabecular load transmission) during regression analysis. In addition, an empirical relationship between permeability and porosity is applied to the collected data. Mean parameters in the superior-inferior (SI) orientation of cubic samples (n=20) harvested from a single bovine distal femur were the largest (p<0.05) in comparison to medial-lateral (ML) and anterior-posterior (AP) orientations: Apparent elastic modulus (2,139 MPa), permeability (4.65x10(-10) m2), and material stiffness coefficient (13.6 GPa). A negative correlation between permeability as a predictor of structural elastic modulus supported a parametric relationship in the ML (R2=0.4793), AP (R2=0.3018), and SI (R2=0.6445) directions (p<0.05).

Entities:  

Mesh:

Year:  2002        PMID: 12405594     DOI: 10.1115/1.1503374

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  7 in total

1.  Fabric dependence of quasi-waves in anisotropic porous media.

Authors:  Luis Cardoso; Stephen C Cowin
Journal:  J Acoust Soc Am       Date:  2011-05       Impact factor: 1.840

2.  Fabric dependence of wave propagation in anisotropic porous media.

Authors:  Stephen C Cowin; Luis Cardoso
Journal:  Biomech Model Mechanobiol       Date:  2010-05-12

3.  A First-Order Mechanical Device to Model Traumatized Craniovascular Biodynamics.

Authors:  Sean S Kohles; Ryan W Mangan; Edward Stan; James McNames
Journal:  J Med Device       Date:  2007-03       Impact factor: 0.582

4.  Single-trabecula building block for large-scale finite element models of cancellous bone.

Authors:  D Dagan; M Be'ery; A Gefen
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

5.  Ultrasonic wave propagation assessment of native cartilage explants and hydrogel scaffolds for tissue engineering.

Authors:  Sean S Kohles; Shelley S Mason; Anya P Adams; Robert J Berg; Jessica Blank; Fay Gibson; Johnathan Righetti; Iesha S Washington; Asit K Saha
Journal:  Int J Biomed Eng Technol       Date:  2012

6.  A temporospatial histomorphometric analysis of bone density adjacent to acid-etched self-tapping dental implants with an external hexagon connection in the female baboon.

Authors:  Lara L Ryan; Sean S Kohles
Journal:  Clin Oral Investig       Date:  2021-09-29       Impact factor: 3.573

7.  Biomechanical considerations on tooth-implant supported fixed partial dentures.

Authors:  Konstantinos X Michalakis; Pasquale Calvani; Hiroshi Hirayama
Journal:  J Dent Biomech       Date:  2012-10-29
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.