Literature DB >> 12405460

A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep.

K W Frisken1, G W Dandie, S Lugowski, G Jordan.   

Abstract

BACKGROUND: Titanium is generally considered a safe metal to use in implantation but some studies have suggested that particulate titanium may cause health problems either at the site overlying the implant or in distant organs, particularly after frictional wear of a medical prosthesis. It was the purpose of this investigation to study the levels of dissemination of titanium from threaded screw type implants following placement of single implants in sheep mandibles.
METHOD: Twelve sheep were implanted with a single 10x3.75mm self-tapping implant for time intervals of one, four and eight to 12 weeks. Four unoperated sheep served as controls. Regional lymph nodes, lungs, spleens and livers were dissected, frozen and subsequently analysed by Graphite Furnace Atomic Absorption Spectroscopy.
RESULTS: Results associated with successful implants showed no statistically significant different levels of titanium in any organ compared to controls, although some minor elevations in titanium levels within the lungs and regional lymph nodes were noted. Two implants failed to integrate and these showed higher levels of titanium in the lungs (2.2-3.8 times the mean of the controls) and regional lymph nodes (7-9.4 times the levels in controls).
CONCLUSIONS: Debris from a single implant insertion is at such a low level that it is unlikely to pose a health problem. Even though the number of failed implants was low, multiple failed implants may result in considerably more titanium release which can track through the regional lymph nodes. Results suggest that sheep would be an excellent model for following biological changes associated with successful and failed implants and the effect this may have on titanium release.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12405460     DOI: 10.1111/j.1834-7819.2002.tb00331.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  20 in total

Review 1.  Electrical implications of corrosion for osseointegration of titanium implants.

Authors:  R A Gittens; R Olivares-Navarrete; R Tannenbaum; B D Boyan; Z Schwartz
Journal:  J Dent Res       Date:  2011-05-09       Impact factor: 6.116

Review 2.  Hypersensitivity to titanium: a less explored area of research.

Authors:  Vasantha Vijayaraghavan; Ajay V Sabane; K Tejas
Journal:  J Indian Prosthodont Soc       Date:  2012-07-13

3.  Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

Authors:  Celha Borges Costa Alves; Márcio Nunes Segurado; Miriam Cristina Leandro Dorta; Fátima Ribeiro Dias; Maurício Guilherme Lenza; Marcos Augusto Lenza
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

4.  Nano-titanium dioxide modulates the dermal sensitization potency of DNCB.

Authors:  Salik Hussain; Stijn Smulders; Vanessa De Vooght; Bert Ectors; Sonja Boland; Francelyne Marano; Kirsten L Van Landuyt; Benoit Nemery; Peter H M Hoet; Jeroen A J Vanoirbeek
Journal:  Part Fibre Toxicol       Date:  2012-05-23       Impact factor: 9.400

5.  Allergy related to dental implant and its clinical significance.

Authors:  Tp Chaturvedi
Journal:  Clin Cosmet Investig Dent       Date:  2013-08-19

6.  One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study.

Authors:  A Siddiqi; W J Duncan; R K De Silva; S Zafar
Journal:  Biomed Res Int       Date:  2016-12-12       Impact factor: 3.411

Review 7.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

8.  Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture.

Authors:  Magdy Mohamed Zaky; Nabila Ali Fayed; Mohamed Farid Shehab
Journal:  Oral Maxillofac Surg       Date:  2019-11-12

Review 9.  Titanium allergy: a literature review.

Authors:  Manish Goutam; Chandu Giriyapura; Sunil Kumar Mishra; Siddharth Gupta
Journal:  Indian J Dermatol       Date:  2014-11       Impact factor: 1.494

10.  Release of titanium after insertion of dental implants with different surface characteristics - an ex vivo animal study.

Authors:  Mattias Pettersson; Jean Pettersson; Margareta Molin Thorén; Anders Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14