Literature DB >> 12397246

The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws.

George K Tzenakis1, William W Nagy, Raymond A Fournelle, Virendra B Dhuru.   

Abstract

STATEMENT OF PROBLEM: Screw loosening and/or fracture is common and has been attributed to many factors, including improper torque and preload. Purpose. This study evaluated the effect of repeated preload torque and salivary contamination on the preload of the slotted gold implant prosthetic screw.
MATERIAL AND METHODS: Fifteen slotted gold prosthetic screws were tested in an unused stack of components consisting of an implant, an abutment cylinder, and a screw and gold cylinder. A custom load frame and load cell and associated electronics were used. The component stack was lubricated with human saliva. Each screw was tightened to 10 Ncm with a hand-held torque wrench fitted with strain gauge electronics and then removed 10 times. Preload values at the first (Group 1X), fifth (Group 5X), and tenth (Group 10X) repetition were measured. Repeated-measures 1-way analysis of variance (P<.05) and paired comparisons were used to analyze the data.
RESULTS: The mean preload value increased from Group 1X (184.3 N +/- 28.9) to Group 5X (202.5 N +/- 27.7) to Group 10X (220.2 N +/- 29.0). The differences among these groups were significant (P=.004).
CONCLUSION: Within the limitations of this study, higher preload was achieved after the repeated use of a saliva-lubricated gold prosthetic retaining screw.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12397246     DOI: 10.1067/mpr.2002.127604

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

1.  Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

Authors:  T Paepoemsin; P A Reichart; P Chaijareenont; F P Strietzel; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

2.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  Preload and torque removal evaluation of three different abutment screws for single standing implant restorations.

Authors:  Rafael Augusto Stüker; Eduardo Rolim Teixeira; João Carlos Pinheiro Beck; Nilza Pereira da Costa
Journal:  J Appl Oral Sci       Date:  2008 Jan-Feb       Impact factor: 2.698

4.  Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

Authors:  Woong-Rae Cho; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

5.  A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants.

Authors:  Felipe Miguel Saliba; Mayra Cardoso; Marcelo Ferreira Torres; Alexandre Carvalho Teixeira; Eduardo José Veras Lourenço; Daniel de Moraes Telles
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

6.  Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

Authors:  Eric W Meisberger; Sjoerd J G Bakker; Marco S Cune
Journal:  Int J Implant Dent       Date:  2015-03-20

Review 7.  Systematic analysis of factors that cause loss of preload in dental implants.

Authors:  S Nithyapriya; A S Ramesh; A Kirubakaran; Jeevitha Mani; J Raghunathan
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

8.  Salvage of fractured abutment screw by transfer cap screw replacement (original study).

Authors:  Rawaa Y Al-Rawee; Fatima A Mohammad; Bashar A Tawfeeq
Journal:  Clin Case Rep       Date:  2019-05-10

9.  Healing Abutment Distortion in Implant Prostheses: An In Vitro Study.

Authors:  Chandrashekhar Pandey; Bishwa Prakash Bhattarai; Apiwat Riddhabhaya; Natthamet Wongsirichat; Dinesh Rokaya
Journal:  J Funct Biomater       Date:  2022-06-21

10.  Comparison of the maximum hand-generated torque by professors and postgraduate dental students for tightening the abutment screws of dental implants.

Authors:  Feridoun Parnia; Javad Yazdani; Parisa Fakour; Farhang Mahboub; Seyyed Mahdi Vahid Pakdel
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.