Literature DB >> 12394875

Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation.

Andrew L Chen1, Thomas N Joseph, Phillip R Wolinksy, Nirmal C Tejwani, Frederick J Kummer, Kenneth A Egol, Kenneth J Koval.   

Abstract

BACKGROUND: This study compared the fixation stability of two treatments for humeral shaft fractures with segmental bone loss during cyclic, physiologic loading.
METHODS: Six matched pairs of human humeri received either a 10-hole broad dynamic compression plate or a locked antegrade inserted humeral nail applied to a humeral diaphyseal osteotomy with a 1.5-cm gap defect. The bone-implant humeral constructs were axially loaded for 10,000 cycles at 250 N and 500 N, with measurements of gap displacement and calculation of construct stiffness. The specimens were then loaded to failure.
RESULTS: Cyclic loading showed no difference between the two groups for average gap displacement or construct stiffness. The intramedullary nail constructs failed by humeral shaft splitting (n = 4) or head cut-out (n = 2) at an average of 958.3 N, whereas the plate constructs failed by humeral shaft splitting and screw pull-out (n = 3) or plate bending (n = 3) at an average of 641.7 N (p < 0.001).
CONCLUSION: Although both methods offer similar fixation stability under physiologic loads, the higher load to failure demonstrated by intramedullary nail fixation may have implications for the patient with multiple injuries for whom partial weightbearing on the injured upper extremity may be necessary.

Entities:  

Mesh:

Year:  2002        PMID: 12394875     DOI: 10.1097/00005373-200210000-00019

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  7 in total

1.  Arthroscopic removal of an intramedullary nail in the humerus.

Authors:  Kyung Cheon Kim; Kwang Jin Rhee; Hyun Dae Shin; Young Mo Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-12-06       Impact factor: 4.342

2.  Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails.

Authors:  Ting-Cheng Chao; Wen-Ying Chou; Jui-Chang Chung; Chien-Jen Hsu
Journal:  Int Orthop       Date:  2005-02-16       Impact factor: 3.075

3.  The treatment of distal third humeral diaphyseal fractures: Is there still a place for the external fixation?

Authors:  N Tartaglia; G Vicenti; M Carrozzo; A Abate; F Rifino; G Picca; G Solarino; B Moretti
Journal:  Musculoskelet Surg       Date:  2016-11-30

4.  Results of the keyhole interlocked nailing for humeral diaphyseal fractures in adults.

Authors:  Wasudeo Gadegone; B Shivashankar; Piyush Gadegone; Vijayanand Lokhande; Yogesh Salphale
Journal:  Int Orthop       Date:  2021-09-08       Impact factor: 3.075

5.  Technical considerations and early results of magnetic compressive intramedullary nailing for humeral shaft delayed unions and nonunions.

Authors:  Daniel J Cognetti; Abdullah Ghali; Jose M Gutierrez-Naranjo; Jordan Handcox; Ravi Karia; Anil K Dutta
Journal:  JSES Int       Date:  2022-01-17

6.  Open Intramedullary Nailing for Segmental Long Bone Fractures: An Effective Alternative in a Resource-restricted Environment.

Authors:  Olasunkanmi M Babalola; Gbadebo Hakeem Ibraheem; Bola A Ahmed; Ayokunle Olawepo; Samuel B Agaja; Adebowale Adeniyi
Journal:  Niger J Surg       Date:  2016 Jul-Dec

7.  EVALUATION OF PATIENTS UNDERGOING FIXATION OF DIAPHYSEAL HUMERAL FRACTURES USING THE MINIMALLY INVASIVE BRIDGE-PLATE TECHNIQUE.

Authors:  Mauro José Superti; Fábio Martynetz; Ricardo Sprenger Falavinha; Rodrigo Caldonazzo Fávaro; Luis Felipe Villas Boas; Salim Mussi Filho; Juliano Martynetz; Bruno Ribas
Journal:  Rev Bras Ortop       Date:  2015-12-06
  7 in total