Literature DB >> 12392950

Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane.

Xiaohong Chen1, Yibai Hu, George S Wilson.   

Abstract

A procedure is described that provides co-immobilization of enzyme and bovine serum albumin (BSA) within an alumina sol-gel matrix and a polyphenol layer permselective for endogenous electroactive species. BSA has first been employed for the immobilization of glucose oxidase (GOx) on a Pt electrode in a sol-gel to produce a uniform, thin and compact film with enhanced enzyme activity. Electropolymerization of phenol was then employed to form an anti-interference and protective polyphenol film within the enzyme layer. In addition, a stability-reinforcing membrane derived from (3-aminopropyl)-trimethoxysilane was constructed by electrochemically-assisted crosslinking. This hybrid film outside the enzyme layer contributed both to the improved stability and to permselectivity. The resulting glucose sensor was characterized by a short response time (<10 s), high sensitivity (10.4 nA/mM mm(2)), low interference from endogenous electroactive species, and a working lifetime of at least 60 days.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12392950     DOI: 10.1016/s0956-5663(02)00093-3

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Edge-plane microwire electrodes for highly sensitive H₂O₂ and glucose detection.

Authors:  Liangliang Qiang; Santhisagar Vaddiraju; Dipesh Patel; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2011-02-18       Impact factor: 10.618

2.  An Amperometric Glucose Sensor Integrated into an Insulin Delivery Cannula: In Vitro and In Vivo Evaluation.

Authors:  W Kenneth Ward; Gabriel Heinrich; Matthew Breen; Sheila Benware; Nicole Vollum; Kristin Morris; Chad Knutsen; Joseph D Kowalski; Scott Campbell; Jerry Biehler; Mark S Vreeke; Scott M Vanderwerf; Jessica R Castle; Robert S Cargill
Journal:  Diabetes Technol Ther       Date:  2017-02-21       Impact factor: 6.118

3.  Fabrication of nitric oxide-releasing porous polyurethane membranes-coated needle-type implantable glucose biosensors.

Authors:  Ahyeon Koh; Yuan Lu; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2013-10-08       Impact factor: 6.986

4.  Enzyme-modified carbon-fiber microelectrode for the quantification of dynamic fluctuations of nonelectroactive analytes using fast-scan cyclic voltammetry.

Authors:  Leyda Z Lugo-Morales; Philip L Loziuk; Amanda K Corder; J Vincent Toups; James G Roberts; Katherine A McCaffrey; Leslie A Sombers
Journal:  Anal Chem       Date:  2013-08-26       Impact factor: 6.986

5.  Investigation on uric acid biosensor model for enzyme layer thickness for the application of arthritis disease diagnosis.

Authors:  P Parthasarathy; S Vivekanandan
Journal:  Health Inf Sci Syst       Date:  2018-04-23

6.  Adaptable Xerogel-Layered Amperometric Biosensor Platforms on Wire Electrodes for Clinically Relevant Measurements.

Authors:  Lillian B Hughes; Najwa Labban; Grace E Conway; Julie A Pollock; Michael C Leopold
Journal:  Sensors (Basel)       Date:  2019-06-06       Impact factor: 3.576

7.  Bacterial exopolysaccharides as a modern biotechnological tool for modification of fungal laccase properties and metal ion binding.

Authors:  Monika Osińska-Jaroszuk; Magdalena Jaszek; Magdalena Starosielec; Justyna Sulej; Anna Matuszewska; Monika Janczarek; Renata Bancerz; Jerzy Wydrych; Adrian Wiater; Anna Jarosz-Wilkołazka
Journal:  Bioprocess Biosyst Eng       Date:  2018-03-26       Impact factor: 3.210

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.