Entrainment of ventricular tachycardia with a permanent biventricular pacemaker.

Jerry C Luck1, Luna Bhatta, Stephen E Artman, Deborah L Wolbrette, Mary Angela Pantelloni, Gerald V Naccarelli.   

Abstract

Biventricular pacing has been introduced as a treatment for congestive heart failure. These devices presently pace and sense from two disparate ventricular sites. Antitachycardia pacing (ATP) is used for termination of sustained monomorphic ventricular tachycardia (VT) and has been incorporated with simultaneous dual site ventricular pacing for treatment of VT. We report a case of entrainment of sustained monomorphic VT in a 62-year-old female with an ischemic cardiomyopathy and VT, who received a biventricular pacemaker-implantable cardioverter defibrillator, Contak CD (Guidant, St. Paul, MN). Biventricular pacing sites were at the right ventricular apex and the middle of the anterior cardiac vein on the left ventricle. The entrained VT has a left bundle branch block and left axis deviation morphology with a cycle length of 350 msec. ATP at 270 msec produced concealed entrainment of an induced VT. Only one pacing site demonstrated capture. The inability to capture both pacing sites simultaneously was the result of ventricular refractoriness at one of the sites during ATP of the VT. The entrance and exit points of the loop for VT appeared to rest between the two pacing sites in the intraventricular septum. This case illustrates one of the sensing limitations of today's biventricular pacing defibrillator systems.

Entities:  

Mesh:

Year:  2002        PMID: 12391427     DOI: 10.1023/a:1020836603746

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  4 in total

1.  Exploring postinfarction reentrant ventricular tachycardia with entrainment mapping.

Authors:  W G Stevenson; P L Friedman; P T Sager; L A Saxon; D Kocovic; T Harada; I Wiener; H Khan
Journal:  J Am Coll Cardiol       Date:  1997-05       Impact factor: 24.094

2.  A new and reliable method of individual ventricular capture identification during biventricular pacing threshold testing.

Authors:  P Yong; C Duby
Journal:  Pacing Clin Electrophysiol       Date:  2000-11       Impact factor: 1.976

3.  Efficacy of biventricular sensing and treatment of ventricular arrhythmias.

Authors:  M Bocchiardo; M Achtelik; F Gaita; H J Trappe; I Lozano; S Higgins; E Daoud; P Yong; C Duby
Journal:  Pacing Clin Electrophysiol       Date:  2000-11       Impact factor: 1.976

4.  Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction.

Authors:  W G Stevenson; H Khan; P Sager; L A Saxon; H R Middlekauff; P D Natterson; I Wiener
Journal:  Circulation       Date:  1993-10       Impact factor: 29.690

  4 in total
  1 in total

Review 1.  [Cardiac resynchronization therapy and arrhythmias].

Authors:  D Böcker; R Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2005-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.