Literature DB >> 12391052

Stent implantation alters coronary artery hemodynamics and wall shear stress during maximal vasodilation.

John F LaDisa1, Douglas A Hettrick, Lars E Olson, Ismail Guler, Eric R Gross, Tobias T Kress, Judy R Kersten, David C Warltier, Paul S Pagel.   

Abstract

Coronary stents improve resting blood flow and flow reserve in the presence of stenoses, but the impact of these devices on fluid dynamics during profound vasodilation is largely unknown. We tested the hypothesis that stent implantation affects adenosine-induced alterations in coronary hemodynamics and wall shear stress in anesthetized dogs (n = 6) instrumented for measurement of left anterior descending coronary artery (LAD) blood flow, velocity, diameter, and radius of curvature. Indexes of fluid dynamics and shear stress were determined before and after placement of a slotted-tube stent in the absence and presence of an adenosine infusion (1.0 mg/min). Adenosine increased blood flow, Reynolds (Re) and Dean numbers (De), and regional and oscillatory shear stress concomitant with reductions in LAD vascular resistance and segmental compliance before stent implantation. Increases in LAD blood flow, Re, De, and indexes of shear stress were observed after stent deployment (P < 0.05). Stent implantation reduced LAD segmental compliance to zero and potentiated increases in segmental and coronary vascular resistance during adenosine. Adenosine-induced increases in coronary blood flow and reserve, Re, De, and regional and oscillatory shear stress were attenuated after the stent was implanted. The results indicate that stent implantation blunts alterations in fluid dynamics during coronary vasodilation in vivo.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12391052     DOI: 10.1152/japplphysiol.00544.2002

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

1.  Enhanced endothelialization on surface modified poly(L-lactic acid) substrates.

Authors:  Hao Xu; Rajendrasing Deshmukh; Richard Timmons; Kytai Truong Nguyen
Journal:  Tissue Eng Part A       Date:  2010-12-18       Impact factor: 3.845

2.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

3.  Potential fluid mechanic pathways of platelet activation.

Authors:  Shawn C Shadden; Sahar Hendabadi
Journal:  Biomech Model Mechanobiol       Date:  2012-07-11

4.  Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches.

Authors:  Peshala T Gamage; Pengfei Dong; Juhwan Lee; Yazan Gharaibeh; Vladislav N Zimin; Luis A P Dallan; Hiram G Bezerra; David L Wilson; Linxia Gu
Journal:  Comput Biol Med       Date:  2021-10-21       Impact factor: 4.589

5.  Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.

Authors:  Jun Ma; Nan Zhao; Lexxus Betts; Donghui Zhu
Journal:  J Mater Sci Technol       Date:  2015-12-24       Impact factor: 8.067

6.  Hemodynamically driven stent strut design.

Authors:  Juan M Jiménez; Peter F Davies
Journal:  Ann Biomed Eng       Date:  2009-05-27       Impact factor: 3.934

7.  Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.

Authors:  John F LaDisa; Lars E Olson; Douglas A Hettrick; David C Warltier; Judy R Kersten; Paul S Pagel
Journal:  Biomed Eng Online       Date:  2005-10-26       Impact factor: 2.819

8.  Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.

Authors:  John F LaDisa; Lars E Olson; Hettrick A Douglas; David C Warltier; Judy R Kersten; Paul S Pagel
Journal:  Biomed Eng Online       Date:  2006-06-16       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.