Literature DB >> 12386771

Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules.

Nevzat Karabulut1, Mustafa Törü, Veli Gelebek, Meltem Gülsün, O Macit Ariyürek.   

Abstract

The purpose of this study was to investigate the diagnostic accuracy of low-dose helical computed tomography by comparing the number of nodules detected at low- and standard-dose CT. The prospective study included 25 patients who were referred to CT scan for the assessment of pulmonary metastases. All patients underwent CT examinations at both standard- (200 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation) and low-dose (50 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation). The number of nodules detected at each protocol was recorded. The size of the nodules was measured electronically and categorized as <3, 3-4.9, 5-6.9, 7-9.9, and >/=10 mm. Finally, the nodules detected at only standard- or low-dose CT were assessed for the underlying causes of discrepancy. In 25 patients, 533 nodules were detected at standard-dose, whereas 518 nodules were observed at low-dose CT. There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT ( p>0.05). Four hundred ninety-one (87.7%) nodules were detected at both standard- or low-dose CT, 42 (7.5%) nodules were observed only at standard-dose CT, and 27 (4.8%) nodules were seen only at low-dose CT. The sensitivity of low-dose CT was 92.5% for all nodules, 88.1% for nodules <5 mm, and 97.4% for nodules >/=5 mm. No significant image artifact interfering with nodule detection was observed at low-dose CT. The low-dose CT protocol used in this study provided images of adequate quality; thus, it can be used reliably in the detection or exclusion of pulmonary nodules.

Entities:  

Mesh:

Year:  2002        PMID: 12386771     DOI: 10.1007/s00330-002-1368-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists.

Authors:  Katharina Marten; Tobias Seyfarth; Florian Auer; Edzard Wiener; Andreas Grillhösl; Silvia Obenauer; Ernst J Rummeny; Christoph Engelke
Journal:  Eur Radiol       Date:  2004-07-03       Impact factor: 5.315

2.  Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT.

Authors:  Dag Wormanns; Karl Ludwig; Florian Beyer; Walter Heindel; Stefan Diederich
Journal:  Eur Radiol       Date:  2004-11-04       Impact factor: 5.315

3.  Incidental findings detection using low tube potential for CT pulmonary angiography.

Authors:  Kanako K Kumamaru; Frank J Rybicki; Rachna Madan; Ritu Gill; Nicole Wake; Andetta R Hunsaker
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-01       Impact factor: 2.357

4.  A set of 4D pediatric XCAT reference phantoms for multimodality research.

Authors:  Hannah Norris; Yakun Zhang; Jason Bond; Gregory M Sturgeon; Anum Minhas; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei; W P Segars
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

5.  Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction.

Authors:  So Won Lee; Yookyung Kim; Sung Shine Shim; Jeong Kyong Lee; Seok Jeong Lee; Yon Ju Ryu; Jung Hyun Chang
Journal:  Eur Radiol       Date:  2014-01-18       Impact factor: 5.315

6.  Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT.

Authors:  Sadi Gündoğdu; Kamran Mahmutyazicioğlu; Hüseyin Ozdemir; Ahmet Savranlar; Kiyasettin Asil
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

7.  Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection.

Authors:  Ji Young Lee; Myung Jin Chung; Chin A Yi; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

Review 8.  Dosimetry of FDG PET/CT and other molecular imaging applications in pediatric patients.

Authors:  Michael J Gelfand
Journal:  Pediatr Radiol       Date:  2008-12-16

9.  Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization.

Authors:  W P Segars; Jason Bond; Jack Frush; Sylvia Hon; Chris Eckersley; Cameron H Williams; Jianqiao Feng; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  Low dose chest CT protocol (50 mAs) as a routine protocol for comprehensive assessment of intrathoracic abnormality.

Authors:  Takeshi Kubo; Yoshiharu Ohno; Mizuki Nishino; Pei-Jan Lin; Shiva Gautam; Hans-Ulrich Kauczor; Hiroto Hatabu
Journal:  Eur J Radiol Open       Date:  2016-04-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.