Literature DB >> 12382971

Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees.

Chun-Hsiung Huang1, Fang-Yuan Ho, Hon-Ming Ma, Chan-Tsung Yang, Jiann-Jong Liau, Hung-Chan Kao, Tai-Horng Young, Cheng-Kung Cheng.   

Abstract

Osteolysis induced by ultrahigh molecular weight polyethylene wear debris has been recognized as the major cause of long-term failure in total joint arthroplasties. In a previous study, the prevalence of intraoperatively identified osteolysis during primary revision surgery was much higher in mobile bearing knee replacements (47%) than in fixed bearing knee replacements (13%). We postulated that mobile bearing knee implants tend to produce smaller sized particles. In our current study, we compared the particle size and morphology of polyethylene wear debris between failed mobile bearing and fixed bearing knees. Tissue specimens from interfacial and lytic regions were extracted during revision surgery of 10 mobile bearing knees (all of the low contact stress (LCS) design) and 17 fixed bearing knees (10 of the porous-coated anatomic (PCA) and 7 of the Miller/Galante design). Polyethylene particles were isolated from the tissue specimens and examined using both scanning electron microscopy and light-scattering analyses. The LCS mobile bearing knees produced smaller particulate debris (mean equivalent spherical diameter: 0.58 microm in LCS, 1.17 microm in PCA and 5.23 microm in M/G) and more granular debris (mean value: 93% in LCS, 77% in PCA and 15% in M/G).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12382971     DOI: 10.1016/S0736-0266(02)00015-3

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  14 in total

1.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Staged bilateral mobile-bearing and fixed-bearing total knee arthroplasty in the same patients: a prospective comparison of a posterior-stabilized prosthesis.

Authors:  Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-20       Impact factor: 4.342

3.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

4.  Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?

Authors:  Karen I Cyndari; Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Timothy A Damron; Kenneth A Mann
Journal:  J Arthroplasty       Date:  2017-02-03       Impact factor: 4.757

5.  NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study.

Authors:  Roberto Rossi; Andrea Ferro; Matteo Bruzzone; Davide Edoardo Bonasia; Giacomo Garzaro; Filippo Castoldi
Journal:  Chir Organi Mov       Date:  2009-04-29

6.  Fixed or mobile-bearing total knee arthroplasty.

Authors:  Chun-Hsiung Huang; Jiann-Jong Liau; Cheng-Kung Cheng
Journal:  J Orthop Surg Res       Date:  2007-01-05       Impact factor: 2.359

7.  Relationship between obesity and early failure of total knee prostheses.

Authors:  Barbara Bordini; Susanna Stea; Sara Cremonini; Marco Viceconti; Rossana De Palma; Aldo Toni
Journal:  BMC Musculoskelet Disord       Date:  2009-03-05       Impact factor: 2.362

8.  Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revision.

Authors:  Markus Rohrbach; Martin Lüem; Peter E Ochsner
Journal:  J Orthop Surg Res       Date:  2008-02-22       Impact factor: 2.359

Review 9.  Outcome of Unicompartmental Knee Arthroplasty: A Systematic Review of Comparative Studies between Fixed and Mobile Bearings Focusing on Complications.

Authors:  Young-Bong Ko; Manan Ramesh Gujarathi; Kwang-Jun Oh
Journal:  Knee Surg Relat Res       Date:  2015-09-01

Review 10.  Biomechanical considerations in the design of high-flexion total knee replacements.

Authors:  Cheng-Kung Cheng; Colin J McClean; Yu-Shu Lai; Wen-Chuan Chen; Chang-Hung Huang; Kun-Jhih Lin; Chia-Ming Chang
Journal:  ScientificWorldJournal       Date:  2014-05-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.