Literature DB >> 12381067

Clinical outcome of Brånemark System implants of various diameters: a retrospective study.

Bertil Friberg1, Annika Ekestubbe, Lars Sennerby.   

Abstract

PURPOSE: The purpose of this study was to evaluate the outcome of the 3 different diameters of Brånemark System implants, with special focus on the 5.0-mm-diameter implant.
MATERIALS AND METHODS: Ninety-eight patients (99 jaws) with a mean age of 62 years were included in this retrospective report. The mean follow-up period was 2 years and 8 months. A total of 379 Brånemark System implants (3.75 mm diameter, n = 146; 4.0 mm diameter, n = 76; 5.0 mm diameter, n = 157) were placed in 29 edentulous and 70 partially edentulous jaws.
RESULTS: Eight of the 146 implants in the 3.75-mm-diameter group failed (5.5%). The corresponding figures for the 4.0- and 5.0-mm-diameter implants were 3 of 76 (3.9%) and 7 of 157 (4.5%), respectively. DISCUSSION: All failures were recorded in maxillae, ie, 18 of the 298 placed, and the majority of these were found in bone quantity group B and quality group 2. Only 3 implants of 131 failed in bone judged as quality 4. The marginal bone loss was low for the 3 implant diameter groups.
CONCLUSION: The favorable outcome in bone of poor quality is ascribed partly to the use of an adapted preparation technique and extended healing periods for achievement of the best primary and secondary implant stability possible.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12381067

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

Review 1.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

2.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

3.  A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation.

Authors:  Daisuke Ueno; Kei Nakamura; Kousuke Kojima; Takeshi Toyoshima; Hideaki Tanaka; Kazuhiko Ueda; Kiyoshi Koyano; Toshiro Kodama
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

4.  Peri-implantitis. Part 2: Prevention and maintenance of peri-implant health.

Authors:  A Alani; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

5.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

Review 6.  Significance of osteoporosis in craniomaxillofacial surgery: a review of the literature.

Authors:  B Hohlweg-Majert; R Schmelzeisen; B M Pfeiffer; E Schneider
Journal:  Osteoporos Int       Date:  2005-07-16       Impact factor: 4.507

7.  Comparison of implant survival with implants placed in acceptable and compromised bone: a literature review.

Authors:  Stefan Ihde; Sigmar Kopp; Thomas Maier
Journal:  J Maxillofac Oral Surg       Date:  2009-06-10

8.  The effect of the thread depth on the mechanical properties of the dental implant.

Authors:  Sun-Young Lee; Sung-Jun Kim; Hyun-Wook An; Hyun-Seung Kim; Dong-Guk Ha; Kyung-Ho Ryo; Kwang-Bum Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

9.  Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Authors:  Maria Piedad Ramírez Fernández; Sergio A Gehrke; Patricia Mazón; Jose L Calvo-Guirado; Piedad N De Aza
Journal:  Materials (Basel)       Date:  2017-06-12       Impact factor: 3.623

10.  Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture.

Authors:  Afsheen Tabassum; Gert J Meijer; Vincent M J I Cuijpers; X Frank Walboomers
Journal:  Saudi Dent J       Date:  2020-03-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.