Literature DB >> 12376894

[Intra- and perioperative complications in the stabilization of per- and subtrochanteric femoral fractures by means of PFN].

W Werner-Tutschku1, G Lajtai, G Schmiedhuber, T Lang, C Pirkl, E Orthner.   

Abstract

In the period from 2/98 up to 6/99, fractures of the proximal femur of 70 patients (phi 79.2 a), were treated with a proximal femur nail (PFN((R))). The aim of this retrospective analysis was to evaluate intra- and perioperative complications. The reports of the operation and the anaesthesia documentation sheets have been worked out, all X-rays have been measured, and evaluated along exactly defined parameters. Problems or complications were found in 18 cases (25,7%). In 7 cases (10,0%) these problems could be solved during operation. The "Z-effect" seen in 5 cases (7,1%) and the "cut-out" of the sliding-hip-screw in 6 cases (8,6%) were the most frequent complications. The main reason was a bad primary reposition in varus with a CCD-Angle less than 125 degrees.

Entities:  

Mesh:

Year:  2002        PMID: 12376894     DOI: 10.1007/s00113-002-0416-5

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  41 in total

1.  Treatment of reverse oblique trochanteric femoral fractures with proximal femoral nail.

Authors:  Korhan Ozkan; Engin Eceviz; Koray Unay; Levent Tasyikan; Budak Akman; Abdullah Eren
Journal:  Int Orthop       Date:  2010-03-28       Impact factor: 3.075

2.  [Treatment results after cemented hemiprosthesis for care of unstable pertrochanteric femoral fractures in the elderly].

Authors:  S Grote; F Stegmeyer; V Bogner; P Biberthaler; W Mutschler
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

Review 3.  [Complication management in implant dislocation].

Authors:  A Lenich; S Siebenlist; A B Imhoff
Journal:  Chirurg       Date:  2015-10       Impact factor: 0.955

4.  [Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws. An experimental study].

Authors:  M C Müller; P Belei; M de la Fuente; M Strake; K Kabir; O Weber; C Burger; K Radermacher; D C Wirtz
Journal:  Unfallchirurg       Date:  2012-09       Impact factor: 1.000

5.  Intrapelvic migration of hip lag screw of proximal femoral nail-sequele to a paradoxical reverse Z effect and their critical analysis.

Authors:  Hitesh Lal; Deepak Kumar Sharma; Deepak Mittal
Journal:  J Clin Orthop Trauma       Date:  2012-06-16

Review 6.  [Pertrochanteric femoral fractures in the elderly].

Authors:  G H Sandmann; P Biberthaler
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

Review 7.  [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

Authors:  F Bonnaire; T Lein; P Bula
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

8.  Pitfalls and complications in the use of the proximal femoral nail.

Authors:  Joachim Windolf; Dirk A Hollander; Mohssen Hakimi; Wolfgang Linhart
Journal:  Langenbecks Arch Surg       Date:  2004-04-15       Impact factor: 3.445

9.  [Proximal femur fractures: results and complications after osteosynthesis with PFN and TGN].

Authors:  M Müller; A Seitz; L Besch; R E Hilgert; A Seekamp
Journal:  Unfallchirurg       Date:  2008-02       Impact factor: 1.000

10.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

View more