Literature DB >> 12374320

Exact frequency-domain reconstruction for thermoacoustic tomography--II: Cylindrical geometry.

Yuan Xu1, Minghua Xu, Lihong V Wang.   

Abstract

Microwave-induced thermoacoustic tomography (TAT) in a cylindrical configuration is developed to image biological tissue. Thermoacoustic signals are acquired by scanning a flat ultrasonic transducer. Using a new expansion of a spherical wave in cylindrical coordinates, we apply the Fourier and Hankel transforms to TAT and obtain an exact frequency-domain reconstruction method. The effect of discrete spatial sampling on image quality is analyzed. An aliasing-proof reconstruction method is proposed. Numerical and experimental results are included.

Mesh:

Year:  2002        PMID: 12374320     DOI: 10.1109/TMI.2002.801171

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Compressed sensing in photoacoustic tomography in vivo.

Authors:  Zijian Guo; Changhui Li; Liang Song; Lihong V Wang
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Design and evaluation of a novel breast cancer detection system combining both thermoacoustic (TA) and photoacoustic (PA) tomography.

Authors:  Manojit Pramanik; Geng Ku; Changhui Li; Lihong V Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

Review 3.  Photoacoustic tomography and sensing in biomedicine.

Authors:  Changhui Li; Lihong V Wang
Journal:  Phys Med Biol       Date:  2009-09-01       Impact factor: 3.609

4.  An adaptive filtered back-projection for photoacoustic image reconstruction.

Authors:  He Huang; Gilbert Bustamante; Ralph Peterson; Jing Yong Ye
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

5.  Biomedical photoacoustic imaging.

Authors:  Paul Beard
Journal:  Interface Focus       Date:  2011-06-22       Impact factor: 3.906

6.  Spatiotemporal Antialiasing in Photoacoustic Computed Tomography.

Authors:  Peng Hu; Lei Li; Li Lin; Lihong V Wang
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

Review 7.  Photoacoustic-guided surgery from head to toe [Invited].

Authors:  Alycen Wiacek; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-03-16       Impact factor: 3.732

Review 8.  Prospects of photoacoustic tomography.

Authors:  Lihong V Wang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Tangential resolution improvement in thermoacoustic and photoacoustic tomography using a negative acoustic lens.

Authors:  Manojit Pramanik; Geng Ku; Lihong V Wang
Journal:  J Biomed Opt       Date:  2009 Mar-Apr       Impact factor: 3.170

10.  Weight factors for limited angle photoacoustic tomography.

Authors:  G Paltauf; R Nuster; P Burgholzer
Journal:  Phys Med Biol       Date:  2009-05-08       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.