Literature DB >> 12368742

Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography.

Paul J Nederkoorn1, Otto E H Elgersma, Willem P Th M Mali, Bert C Eikelboom, L Jaap Kappelle, Yolanda van der Graaf.   

Abstract

BACKGROUND AND
PURPOSE: Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) is generally considered to overestimate the degree of stenosis in the internal carotid artery (ICA) in comparison with the reference standard intraarterial digital subtraction angiography (DSA). We evaluated whether the degree of stenosis was more accurately assessed with 3D TOF MRA if corresponding projections on MRA and DSA were compared instead of comparison of maximal stenosis at MRA with maximal stenosis at DSA.
METHODS: From February 1997 to December 1999, we included 186 symptomatic and 17 asymptomatic consecutive patients suspected of having carotid artery stenosis on the basis of clinical presentation and screening with duplex ultrasound scan examination. All patients subsequently underwent DSA and MRA imaging. From each ICA, 12 maximum intensity projections with 3D TOF MRA and two or three projections with DSA were obtained. First, we compared the maximal stenosis at MRA with the maximal stenosis at DSA. Subsequently, we used the stenosis at MRA measured on the projection corresponding with the DSA projection that showed the maximal stenosis. For both strategies, the mean differences in stenosis and sensitivity and specificity for assessment of severe stenosis (70% to 99%) were calculated and compared.
RESULTS: The MRA and DSA images of 354 ICAs could be compared. The sensitivity and specificity of MRA with the projection that showed the maximal stenosis were 92.6% (95% CI, 85.3% to 97.0%) and 82.7% (95% CI, 78.1% to 87.3%), respectively. The sensitivity and specificity with the MRA projection, corresponding with the DSA projection showing the maximal stenosis, were 88.3% (95% CI, 81.8% to 94.8%) and 89.6% (95% CI, 85.9% to 93.3%), respectively. The mean difference between maximal stenosis at MRA and DSA was 7.5% (95% CI, 5.2% to 9.9%). The mean difference between stenosis at MRA and DSA in corresponding projections was 0.4% (95% CI, -2.0% to 2.7%).
CONCLUSION: If corresponding MRA and intraarterial DSA projections are compared, 3D TOF MRA does not overestimate carotid stenosis.

Entities:  

Mesh:

Year:  2002        PMID: 12368742

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  16 in total

1.  Flow voids and carotid MR angiography.

Authors:  Joseph E Heiserman
Journal:  AJNR Am J Neuroradiol       Date:  2003-09       Impact factor: 3.825

2.  [CTA of carotid artery with different scanner types].

Authors:  M Lell; K Anders; C Leidecker; W Lang; W Bautz; M Uder
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

3.  [The significance of MR angiography for the diagnosis of carotid stenoses].

Authors:  H J Michaely; K A Herrmann; H Kramer; G Laub; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

4.  [CT diagnostics of carotid artery stenosis].

Authors:  W Reith; C Roth
Journal:  Radiologe       Date:  2010-07       Impact factor: 0.635

5.  Non-ECG-gated unenhanced MRA of the carotids: optimization and clinical feasibility.

Authors:  H Raoult; J Y Gauvrit; P Schmitt; V Le Couls; E Bannier
Journal:  Eur Radiol       Date:  2013-06-20       Impact factor: 5.315

6.  Delivery of Polymeric Nanoparticles to Target Vascular Diseases.

Authors:  Edward Agyare; Karunyna Kandimalla
Journal:  J Biomol Res Ther       Date:  2014-01

7.  Performance of semiautomatic assessment of carotid artery stenosis on CT angiography: clarification of differences with manual assessment.

Authors:  H A Marquering; P J Nederkoorn; L Smagge; H A Gratama van Andel; R van den Berg; C B Majoie
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-22       Impact factor: 3.825

Review 8.  False-negative magnetic resonance angiography with extracranial internal carotid artery stenosis: a report of two cases and review of the literature.

Authors:  Wayne M Gluf; Brent O'Neill; William T Couldwell
Journal:  Neurosurg Rev       Date:  2004-10-08       Impact factor: 3.042

9.  Assessment of carotid artery atherosclerotic disease by using three-dimensional fast black-blood MR imaging: comparison with DSA.

Authors:  Huilin Zhao; Jinnan Wang; Xiaosheng Liu; Xihai Zhao; Daniel S Hippe; Ye Cao; Jieqing Wan; Chun Yuan; Jianrong Xu
Journal:  Radiology       Date:  2014-10-03       Impact factor: 11.105

10.  Reproducibility of Middle Cerebral Artery Stenosis Measurements by DSA: Comparison of the NASCET and WASID Methods.

Authors:  Luguang Chen; Qian Zhan; Chao Ma; Qi Liu; Xuefeng Zhang; Xia Tian; Yuanliang Jiang; Yinmei Dong; Shiyue Chen; Jianping Lu
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.