Combined Baerveldt glaucoma drainage implant and trabeculectomy with mitomycin C for refractory glaucoma.

Donald L Budenz1, Ingrid U Scott, Quang H Nguyen, William Feuer, Kuldev Singh, Marcelo T Nicolela, Michael Bueche, Paul F Palmberg.   

Abstract

PURPOSE: To describe the surgical technique and clinical outcomes of a procedure for refractory glaucoma, concurrent Baerveldt glaucoma implant (BGI) and trabeculectomy with mitomycin C.
MATERIALS AND METHODS: Medical records of all patients who underwent combined Prolene-ligated BGI and trabeculectomy with mitomycin C were retrospectively reviewed. Main outcome measures were intraocular pressure (IOP), number of glaucoma medications, visual acuity, and complications. Kaplan-Meier survival analysis was used to determine success, defined as IOP < 22 mm Hg, no reoperation for glaucoma, and no loss of light perception vision.
RESULTS: The mean +/- SD follow-up period for 38 eyes of 36 patients was 34 +/- 36 months (range, 3-121 months), during which 18 of 38 eyes (47%) required laser suture lysis of the Prolene suture. Intraocular pressure was reduced from a mean (+/- SD) preoperative value of 35.7 +/- 12.8 to 12.7 +/- 4.7 mm Hg at 1-year follow-up and 11.9 +/- 5.5 mm Hg at the last follow-up visit ( < 0.001). Number of medicines used for glaucoma was reduced from a mean +/- SD preoperative value of 2.5 +/- 0.9 to 0.5 +/- 0.6 at 1-year follow-up and 0.6 +/- 0.8 at the last follow-up visit ( < 0.001). LogMar visual acuity remained stable at mean of 1.15 +/- 0.85 preoperatively, compared with 1.14 +/- 1.05 at 1-year follow-up, but declined to 1.61 +/- 1.01 at the last follow-up visit, a loss of an average of four lines of vision ( = 0.004). Cumulative success was 91% at year 1, 86% at year 2, and 81% at year 3. Three eyes (8%) had suprachoroidal hemorrhages, one eye (3%) needed reoperation for an extruded implant, one (3%) eye had poor vision due to chronic hypotony, three eyes (8%) required additional glaucoma surgery during the postoperative period, and one eye (3%) needed revision of the implant for pressure control.
CONCLUSIONS: Combined BGI and mitomycin C trabeculectomy provides excellent postoperative IOP control in patients with refractory glaucoma.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12362086     DOI: 10.1097/00061198-200210000-00013

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  7 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

2.  Implantation of a second glaucoma drainage device.

Authors:  Brian A Francis; Rodrigo A B Fernandes; Handan Akil; Vikas Chopra; Bruno Diniz; James Tan; Alex Huang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-07       Impact factor: 3.117

3.  Deep sclerectomy for uveitic glaucoma: long-term outcomes.

Authors:  K Mercieca; L Steeples; N Anand
Journal:  Eye (Lond)       Date:  2017-06-23       Impact factor: 3.775

4.  Outcomes of same-site re-operation with minimal use of mitomycin in failed trabeculectomy.

Authors:  Yadollah Eslami; Vafa Samarai; Massood Mohammadi; Ghasem Fakhraie; Reza Zarei; Sajad Eslami; Sasan Moghimi
Journal:  Int Ophthalmol       Date:  2013-08-14       Impact factor: 2.031

5.  Long-term results of non-valved glaucoma drainage implant surgery and glaucoma drainage implant combined with trabeculectomy.

Authors:  Teruhiko Hamanaka; Keiko Otora; Koichi Ono; Nobuo Ishida
Journal:  Indian J Ophthalmol       Date:  2014-09       Impact factor: 1.848

Review 6.  Aqueous shunt implantation in glaucoma.

Authors:  Jing Wang; Keith Barton
Journal:  Taiwan J Ophthalmol       Date:  2017 Jul-Sep

Review 7.  The Early Postoperative Complications of Two Different Tube Ligation Methods in Baerveldt Implant Surgery.

Authors:  Shuri Kawamorita; Teruhiko Hamanaka; Testurou Sakurai
Journal:  J Curr Glaucoma Pract       Date:  2015-01-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.