Accuracy of inhomogeneity correction in photon radiotherapy from CT scans with different settings.

Huaiqun Guan1, Fang-Fang Yin, Jae Ho Kim.   

Abstract

We report an investigation on the accuracy of inhomogeneity correction in photon radiotherapy from CT scans with different settings. Specifically, the dosimetric differences from different CT scan parameters (kV, mAs) to phantoms and from different Hounsfield unit versus electron density (HU-ED) curves to patients are investigated. The absolute dose per monitor units (dose/MU) is used to quantify the results. We found that only for high-density bones (cranium, femoral tube, etc) using small field 18 MV beams, the dose/MU is up to 2% higher for CT scans using 80 kV than for 130 kV at a depth just beyond the bone and is up to 1-1.5% higher for CT scans using 80 mAs than for 300 mAs. For low-density bones (such as femoral head) and lung, the difference is 1% or less with different kV or mAs settings. The dose/MU varies with different HU-ED curves by up to 2%. The HU-ED curve from the stochiometric calibration was found to be more accurate based on a real measurement. A simplified 4-point curve provides nearly the same accuracy as the stochiometric calibration and may be used as an alternative for routine clinical application.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12361225     DOI: 10.1088/0031-9155/47/17/402

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Computed tomography as a source of electron density information for radiation treatment planning.

Authors:  Witold Skrzyński; Sylwia Zielińska-Dabrowska; Marta Wachowicz; Wioletta Slusarczyk-Kacprzyk; Paweł F Kukołowicz; Wojciech Bulski
Journal:  Strahlenther Onkol       Date:  2010-05-17       Impact factor: 3.621

2.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review.

Authors:  Anne T Davis; Antony L Palmer; Andrew Nisbet
Journal:  Br J Radiol       Date:  2017-05-23       Impact factor: 3.039

4.  Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Youcef El-Mohri; Larry E Antonuk; Qihua Zhao
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

5.  Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique.

Authors:  Langechuan Liu; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Hao Jiang
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

6.  Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center's anthropomorphic thorax phantom used for RTOG credentialing.

Authors:  Stephen F Kry; Paola Alvarez; Andrea Molineu; Carrie Amador; James Galvin; David S Followill
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-01-01       Impact factor: 7.038

7.  Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Richard B Choroszucha; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

Review 8.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

9.  Commissioning and implementation of a stereotactic conformal radiotherapy technique using a general-purpose planning system.

Authors:  M Amin Mosleh-Shirazi; Vibeke N Hansen; Peter J Childs; Alan P Warrington; Frank H Saran
Journal:  J Appl Clin Med Phys       Date:  2004-07-01       Impact factor: 2.102

10.  Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study.

Authors:  Peter G F Watson; Ernesto Mainegra-Hing; Nada Tomic; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.