Literature DB >> 12361212

On the de-noising of Monte Carlo calculated dose distributions.

I Kawrakow1.   

Abstract

This paper presents an algorithm for de-noising Monte Carlo calculated dose distributions for use in radiation treatment planning. The algorithm is a three-dimensional generalization of a Savitzky-Golay digital filter and uses an adaptive smoothing window size to reduce the probability for systematic bias. The paper also introduces five accuracy criteria that are relevant for the expected clinical use of Monte Carlo techniques, which can be used to evaluate the performance of smoothing algorithms. Using these accuracy criteria it is demonstrated that the smoothing algorithm presented here decreases the uncertainty of Monte Carlo calculated dose distributions. The corresponding decrease in necessary particle tracks ranges from a factor of 2 to a factor of 20, depending on the accuracy criterion used. It is shown that very short Monte Carlo simulations combined with smoothing deliver satisfactory dose distributions and may therefore be extremely valuable for the initial trial and error phase of the radiation treatment planning process.

Mesh:

Substances:

Year:  2002        PMID: 12361212     DOI: 10.1088/0031-9155/47/17/304

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  A method to improve accuracy and precision of water surface identification for photon depth dose measurements.

Authors:  J D Ververs; M J Schaefer; I Kawrakow; J V Siebers
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

2.  Monte Carlo modeling of a Novalis Tx Varian 6 MV with HD-120 multileaf collimator.

Authors:  Luis Alberto Vazquez-Quino; Brian Massingill; Chengyu Shi; Alonso Gutierrez; Carlos Esquivel; Tony Eng; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

3.  XDose: toward online cross-validation of experimental and computational X-ray dose estimation.

Authors:  Philipp Roser; Annette Birkhold; Alexander Preuhs; Philipp Ochs; Elizaveta Stepina; Norbert Strobel; Markus Kowarschik; Rebecca Fahrig; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-12-04       Impact factor: 2.924

4.  The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant - comparison with measurements and Monte Carlo calculations.

Authors:  Jarkko Ojala; Mika Kapanen; Petri Sipilä; Simo Hyödynmaa; Maunu Pitkänen
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

5.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

6.  Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study.

Authors:  Peter G F Watson; Ernesto Mainegra-Hing; Nada Tomic; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

7.  Recommended dose voxel size and statistical uncertainty parameters for precision of Monte Carlo dose calculation in stereotactic radiotherapy.

Authors:  Simon K Goodall; Martin A Ebert
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.102

8.  Monte Carlo simulation of 6-MV dynamic wave VMAT deliveries by Vero4DRT linear accelerator using EGSnrc moving sources.

Authors:  Maryam Rostamzadeh; Yoshitomo Ishihara; Mitsuhiro Nakamura; I Antoniu Popescu; Ante Mestrovic; Ermias Gete; Roberto Fedrigo; Alanah Mary Bergman
Journal:  J Appl Clin Med Phys       Date:  2020-11-21       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.