Literature DB >> 12361150

Refractive lens exchange with an array multifocal intraocular lens.

H Burkhard Dick1, Susanne Gross, Mana Tehrani, Dieter Eisenmann, Norbert Pfeiffer.   

Abstract

PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL).
METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO).
RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 +/- 3.25 D (-1.75 to -15.50 D), and group B (n=26; hyperopia, average preoperative spherical equivalent refraction +3.04 +/- 1.04 D). Follow-up was 6 months in all eyes. Postoperatively, all eyes of both groups were within +/-1.00 D of target refraction. No eye in group A and three eyes in group B sustained a loss of one line of BSCVA. Forty-seven eyes (94%) remained unchanged or gained one or more lines of their preoperative BSCVA. In all eyes, postoperative UCVA was 20/40 or better. When compared to preoperative, uncorrected near visual acuity improved (statistically significant). All patients achieved uncorrected binocular visual acuity of 20/30 and J4 or better. Patient satisfaction was extremely high; no intra- or postoperative complications were reported.
CONCLUSION: Six-month results of implantation of the AMO Array multifocal IOL for refractive lens exchange demonstrated safety, efficacy, and predictability in correcting high ametropia and significant improvement of uncorrected near and distance visual acuity.

Entities:  

Mesh:

Year:  2002        PMID: 12361150     DOI: 10.3928/1081-597X-20020901-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

2.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

Review 3.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

4.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

5.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

  5 in total