A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry.

Christian Neusüss1, Matthias Pelzing, Marcus Macht.   

Abstract

A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) approach has been developed for routine application in proteomic studies. Robustness of the coupling is achieved by using a standard coaxial sheath-flow sprayer. Thereby, greater stability than nanoelectrospray ionization-mass spectrometry coupling of sheathless capillary electrophoresis or nanoliquid chromatography (nano-LC) is achieved, resulting in stable operation for several weeks and unattended overnight sequences. The applied sheath flow is reduced to 1-2 microL/min in order to increase sensitivity. Standard peptides and those of digests of standard proteins and gel-separated proteins can be detected in the low femtomole range (full scan and MS/MS). Detection limits are found to be as low as 500 amol. Low femtomole amounts are required for unequivocal identification by MS/MS experiments in the ion trap and subsequent database search. By applying a simple pH-mediated stacking the concentration sensitivity can be lowered to some tens of fmol/microL (nM), depending on capillary size. This sensitivity is close to published values for sheathless CE-MS and nano-LC-MS, respectively (a comparison to reference values is presented). Moreover, with capillaries of about 50 cm in length separations in less than 10 min are possible resulting in a throughput of up to four analyses per hour. This is a factor of 4-12 times faster than nano-LC separation, being the state-of-the-art techniques for proteomic studies.

Mesh:

Substances:

Year:  2002        PMID: 12298087     DOI: 10.1002/1522-2683(200209)23:18<3149::AID-ELPS3149>3.0.CO;2-8

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  7 in total

Review 1.  Mass spectrometry based proteomics in urine biomarker discovery.

Authors:  Dan Theodorescu; Harald Mischak
Journal:  World J Urol       Date:  2007-08-17       Impact factor: 4.226

2.  High-resolution proteome/peptidome analysis of peptides and low-molecular-weight proteins in urine.

Authors:  Harald Mischak; Bruce A Julian; Jan Novak
Journal:  Proteomics Clin Appl       Date:  2007-07-10       Impact factor: 3.494

3.  Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection.

Authors:  Roza Wojcik; Yihan Li; Michael J Maccoss; Norman J Dovichi
Journal:  Talanta       Date:  2011-11-29       Impact factor: 6.057

Review 4.  Adapting mass spectrometry-based platforms for clinical proteomics applications: The capillary electrophoresis coupled mass spectrometry paradigm.

Authors:  Jochen Metzger; Peter B Luppa; David M Good; Harald Mischak
Journal:  Crit Rev Clin Lab Sci       Date:  2009       Impact factor: 6.250

Review 5.  Challenges of using mass spectrometry as a bladder cancer biomarker discovery platform.

Authors:  Eric Schiffer; Harald Mischak; Dan Theodorescu; Antonia Vlahou
Journal:  World J Urol       Date:  2008-01-04       Impact factor: 4.226

6.  Current awareness on comparative and functional genomics.

Authors: 
Journal:  Comp Funct Genomics       Date:  2003

7.  Improvement of derivatized amino acid detection sensitivity in micellar electrokinetic capillary chromatography by means of acid-induced pH-mediated stacking technique.

Authors:  Szymon Dziomba; Adrian Bekasiewicz; Adam Prahl; Tomasz Bączek; Piotr Kowalski
Journal:  Anal Bioanal Chem       Date:  2014-08-22       Impact factor: 4.142

  7 in total