Literature DB >> 12296925

Single-center experience with the bicarbon bileaflet prosthetic heart valve in Japan.

Yoshio Misawa1, Tsutomu Saito, Hiroaki Konishi, Shin-ichi Oki, Yuichiro Kaminishi, Yasuhiro Tezuka, Kei Aizawa, Hideki Takahashi, Nobuyuki Hasegawa, Osamu Kamisawa, Morito Kato, Katsuo Fuse.   

Abstract

We analyzed midterm results using the Bicarbon valve in a single center. Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 +/- 11.3 years. The mean follow-up was 1.8 +/- 1.1 years with a cumulative follow-up of 188 patient-years. There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 5 late deaths (2.7% per patient-year: 3 malignancy, 1 cerebral hemorrhage, 1 myocardial infarction). Survival at 3 years was 91 +/- 4% in the AVR group, 92 +/- 5% in the MVR group, and 66 +/- 23% in the DVR group. The linearized incidence of thromboembolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 1.06 +/- 2.34%, 1.60 +/- 2.53%, and 0.53 +/- 2.22% per patient-year, respectively. No other complications were observed. In conclusion, the Bicarbon prosthetic heart valve has shown excellent clinical results associated with a low incidence of valve-related complications.

Entities:  

Mesh:

Year:  2002        PMID: 12296925     DOI: 10.1046/j.1525-1594.2002.06987.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Clinical experience with the Bicarbon heart valve prosthesis.

Authors:  Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Shin-Ichi Oki; Yuichiro Kaminishi; Yasuhito Sakano; Hideki Morita; Kei Aizawa
Journal:  J Cardiothorac Surg       Date:  2007-01-25       Impact factor: 1.637

2.  Fifteen-year experience with the Bicarbon heart valve prosthesis in a single center.

Authors:  Yoshio Misawa; Arata Muraoka; Shin-ichi Ohki; Kei Aizawa; Koji Kawahito; Tsutomu Saito; Hirotaka Sato; Ippei Takazawa; Soki Kurumisawa; Hirohiko Akutsu; Akira Sugaya
Journal:  J Cardiothorac Surg       Date:  2015-06-28       Impact factor: 1.637

3.  Low-dose anticoagulation after isolated mechanical aortic valve replacement with Liva Nova Bicarbon prosthesis: A post hoc analysis of LOWERING-IT Trial.

Authors:  Michele Torella; Iolanda Aquila; Paolo Chiodini; Cristiano Amarelli; Gianpaolo Romano; Ester Elena Della Ratta; Marisa De Feo; Alessandro Della Corte; Ciro Indolfi; Daniele Torella; Luca Salvatore De Santo
Journal:  Sci Rep       Date:  2018-05-30       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.