Literature DB >> 12296566

Early experience with a polymethyl pentene oxygenator for adult extracorporeal life support.

Giles J Peek1, Hilliary M Killer, Richard Reeves, Andrezj W Sosnowski, Richard K Firmin.   

Abstract

Silicone oxygenators are the standard devices used for Extracorporeal Life Support (ECLS), but they have some limitations. Microporous polypropylene hollow fiber oxygenators overcome many of these problems but, unfortunately, develop plasma leak. Polymethyl-pentene (PMP) is a novel oxygenator material. We report our initial experience with the Medos Hilite 7000LT, a PMP hollow fiber oxygenator, in six adult respiratory ECLS patients with these characteristics: age, mean 32.2 (+/-13) years; weight, mean 81.2 (+/-17) kg; PaO2/FIO2, mean 62.8 [+/-33] mm Hg; Murray Score, mean 3.4 [+/-0.3]; and sepsis related organ failure assessment score, mean 9.6 [+/-2.3]. One patient was cannulated within 10 hours of multiple trauma and 1 hour after thoracolaparotomy; another patient was cannulated 12 hours after a thoracotomy. All six patients survived. Heparin was infused (7.8-32.5 u/kg/hr) to maintain activated clotting time at 162 to 238 seconds; international normalized ratio was 0.9 to 3.4. Two of the six patients required transfusions of fresh frozen plasma, receiving one and five units, respectively. Fibrinogen was 1.4 to 6 g/dl; no cryoprecipitate was needed. Platelet counts were between 65 and 306, and very little platelet transfusion (mean 2.33; +/-3.03 units per patient) was required to maintain these levels. Two patients did not require any platelet transfusion. Maximum blood flow was 5.3 L/min, sweep was 3 to 10 L/min, and resistance was 11 to 43 Paul Wood Units. There were no oxygenator failures. Mean duration of ECLS was 151.7 hours (+/-75.6). Our initial experience with PMP oxygenators in adults was satisfactory, and platelet consumption and resistance to blood flow seem to be greatly reduced with PMP.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12296566     DOI: 10.1097/00002480-200209000-00007

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  17 in total

Review 1.  Contemporary extracorporeal membrane oxygenation for adult respiratory failure: life support in the new era.

Authors:  Graeme MacLaren; Alain Combes; Robert H Bartlett
Journal:  Intensive Care Med       Date:  2011-12-07       Impact factor: 17.440

2.  Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Authors:  Alfred H Stammers; Randi Miller; Stephen G Francis; Laszlo Fuzesi; Anthony Nostro; Eric Tesdahl
Journal:  J Extra Corpor Technol       Date:  2017-06

Review 3.  Emergency cardiac surgery in patients with acute coronary syndromes: a review of the evidence and perioperative implications of medical and mechanical therapeutics.

Authors:  Charles Brown; Brijen Joshi; Nauder Faraday; Ashish Shah; David Yuh; Jeffrey J Rade; Charles W Hogue
Journal:  Anesth Analg       Date:  2011-03-08       Impact factor: 5.108

4.  Preclinical study of a novel hydrodynamically levitated centrifugal pump for long-term cardiopulmonary support : In vivo performance during percutaneous cardiopulmonary support.

Authors:  Tomonori Tsukiya; Toshihide Mizuno; Yoshiaki Takewa; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2015-05-15       Impact factor: 1.731

Review 5.  Temporary support strategies for cardiogenic shock: extracorporeal membrane oxygenation, percutaneous ventricular assist devices and surgically placed extracorporeal ventricular assist devices.

Authors:  Howard Todd Massey; Jae Hwan Choi; Elizabeth J Maynes; Vakhtang Tchantchaleishvili
Journal:  Ann Cardiothorac Surg       Date:  2019-01

6.  Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: analysis of 317 cases with four different ECMO systems.

Authors:  Karla Lehle; Alois Philipp; Karl-Anton Hiller; Florian Zeman; Dirk Buchwald; Christof Schmid; Christian Dornia; Dirk Lunz; Thomas Müller; Matthias Lubnow
Journal:  Intensive Care Med       Date:  2014-10-17       Impact factor: 17.440

7.  Long-term mortality in patients with chronic obstructive pulmonary disease following extracorporeal membrane oxygenation for cardiac assist after cardiovascular surgery.

Authors:  Klaus Distelmaier; Alexander Niessner; Dominik Haider; Irene M Lang; Gottfried Heinz; Gerald Maurer; Herbert Koinig; Barbara Steinlechner; Georg Goliasch
Journal:  Intensive Care Med       Date:  2013-04-24       Impact factor: 17.440

Review 8.  [Extracorporeal membrane oxygenation by acute respiratory distress syndrome].

Authors:  R Kopp; D Henzler; R Dembinski; R Kuhlen
Journal:  Anaesthesist       Date:  2004-02       Impact factor: 1.041

9.  Extracorporeal membrane oxygenation circuitry.

Authors:  Laurance Lequier; Stephen B Horton; D Michael McMullan; Robert H Bartlett
Journal:  Pediatr Crit Care Med       Date:  2013-06       Impact factor: 3.624

Review 10.  Bench to bedside review: Extracorporeal carbon dioxide removal, past present and future.

Authors:  Matthew E Cove; Graeme MacLaren; William J Federspiel; John A Kellum
Journal:  Crit Care       Date:  2012-09-21       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.