Literature DB >> 12220996

Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models.

T Nagasao1, M Kobayashi, Y Tsuchiya, T Kaneko, T Nakajima.   

Abstract

PURPOSE: To calculate the location and intensity of the maximum stresses occurring around implants in the reconstructed mandible.
MATERIAL AND METHODS: Human preserved mandibles and fibulae were used to design 3-D mandibular models on a Desktop Computer. Various 3-D simulation models representing mandibles were made. Implants (fixtures) and superstructures were then embedded in each model and occlusal pressure was applied to the cantilever portion of the superstructure. Von Mises stress, the maximum and minimum principal stress on each model were calculated using finite element structural analysis software. Finally, evaluation of the stresses around each fixture hole was performed.
RESULTS: It appeared that for each fixture hole, the direction and the magnitude of the stresses were influenced by complex factors such as the thickness of the cortical bone where the fixtures were embedded, the degree of vertical displacement under load, and the relationship between adjacent fixtures.
CONCLUSION: Location and intensity of the stresses occurring around fixtures differs significantly between various types of mandibular reconstruction. Published by Elsevier Science Ltd. Copyright 2002 European Association for Cranio-Maxillofacial Surgery.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12220996     DOI: 10.1054/jcms.2002.0310

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  7 in total

1.  Use of finite element analysis in presurgical planning: treatment of mandibular fractures.

Authors:  E P Kavanagh; C Frawley; G Kearns; F Wallis; T McGloughlin; J Jarvis
Journal:  Ir J Med Sci       Date:  2008-09-18       Impact factor: 1.568

2.  Comparison of Stresses Around Dental Implants Placed in Normal and Fibula Reconstructed Mandibular Models using Finite Element Analysis.

Authors:  Thiyaneswaran Nesappan; Padma Ariga
Journal:  J Clin Diagn Res       Date:  2014-08-20

3.  FEM analysis of a new miniplate: stress distribution on the plate, screws and the bone.

Authors:  Didem Nalbantgil; Murat Tozlu; Fulya Ozdemir; Mehmet Oguz Oztoprak; Tulin Arun
Journal:  Eur J Dent       Date:  2012-01

4.  3D Finite Element Study on: Bar Splinted Implants Supporting Partial Denture in the Reconstructed Mandible.

Authors:  Mohamed El-Anwar; Rami Ghali; Mona Aboelnagga
Journal:  Open Access Maced J Med Sci       Date:  2016-02-09

5.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

6.  Stability of internal fixation systems based on different subtypes of Schatzker II fracture of the tibial plateau: A finite element analysis.

Authors:  Chuyang Zeng; Xiaomeng Ren; Cheng Xu; Mengmeng Hu; Jiantao Li; Wei Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-07

7.  Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible.

Authors:  Kyung-Hoi Heo; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.