Literature DB >> 12216039

Polyethylene liner exchange for excessive wear and osteolysis.

Kevin M Terefenko1, Christi J Sychterz, Karl Orishimo, Charles A Engh.   

Abstract

To determine if polyethylene liner exchange of a total hip arthroplasty decreased wear and slowed the progression of osteolysis, we evaluated 10 hips at a mean 6.2 years after component exchange. Head penetration and lesion size were quantified on serial radiographs using computer-assisted techniques. A mean 7.9 years before component exchange, true polyethylene wear rates averaged 0.36 +/- 0.19 mm/y. A mean 6.2 years after component exchange, average wear rates decreased to 0.17 +/- 0.11 mm/y. Similarly, mean acetabular and mean femoral lesion growth rates decreased. At last follow-up, all components remained radiographically stable. Complications included dislocation (1 patient) and increased wear (2 patients). Modular component exchange with removal of granulomatous tissue has the potential to decrease wear and slow the progression of osteolysis without subsequent component loosening. Copyright 2002, Elsevier Science (USA).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12216039     DOI: 10.1054/arth.2002.32705

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Liner exchange and bone grafting: rare option to treat wear & lysis of stable TKAs.

Authors:  John J Callaghan; Eric R Reynolds; Nicholas T Ting; Devon D Goetz; John C Clohisy; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

2.  The fate of grafting acetabular defects during revision total hip arthroplasty.

Authors:  Nathan A Mall; Ryan M Nunley; Kirk E Smith; William J Maloney; John C Clohisy; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

4.  Correlation of computed tomography with histology in the assessment of periprosthetic defect healing.

Authors:  Stephen D Cook; Laura P Patron; Samantha L Salkeld; Kirk E Smith; Bruce Whiting; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2009-12       Impact factor: 4.176

5.  Reconstruction options for acetabular revision.

Authors:  Erica D Taylor; James A Browne
Journal:  World J Orthop       Date:  2012-07-18

6.  Granuloma debridement and the use of an injectable calcium phosphate bone cement in the treatment of osteolysis in an uncemented total knee replacement.

Authors:  Henry D Atkinson; Vijai S Ranawat; Roger D Oakeshott
Journal:  J Orthop Surg Res       Date:  2010-04-27       Impact factor: 2.359

7.  [Preservation of hip prosthesis with local surgical revision and creation of a fistula persistens : an option for palliative treatment of periprosthetic infection in old, polymorbid patients?].

Authors:  A H Tiemann; L Homagk; M Diefenbeck; T Mückley; G O Hofmann
Journal:  Unfallchirurg       Date:  2007-12       Impact factor: 1.000

8.  Acetabular Cup Revision.

Authors:  Young-Ho Kim
Journal:  Hip Pelvis       Date:  2017-09-06

9.  Isolated Acetabular Liner Exchange for Polyethylene Wear and Osteolysis with Well-Fixed Metal Shell.

Authors:  Kyung Wook Kim; Jeong Joon Yoo; Min Nyun Kim; Hee Joong Kim
Journal:  Clin Orthop Surg       Date:  2019-08-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.