Literature DB >> 12204234

Texture analysis of lesions in breast ultrasound images.

Radhika Sivaramakrishna1, Kimerly A Powell, Michael L Lieber, William A Chilcote, Raj Shekhar.   

Abstract

We investigate the use of Haralick's texture features and posterior acoustic attenuation descriptors (PAAD) for the characterization of ultrasound (US) breast lesions. 71 lesions (24 cyst, 21 benign solid mass and 26 malignant solid masses) were manually segmented on two-dimensional breast US images. 28 Haralick's descriptors and two PAAD were evaluated on these segmented lesions. Mean of Sum Average, Range of Sum Entropy and the second PAAD best discriminated cysts from noncysts. Range of Correlation and the second PAAD best discriminated solid malignant from benign lesions. Computerized analysis of breast US images can increase the specificity of breast sonography by providing a better characterization of solid lesions.

Entities:  

Mesh:

Year:  2002        PMID: 12204234     DOI: 10.1016/s0895-6111(02)00027-7

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  13 in total

1.  Radiomics: a new application from established techniques.

Authors:  Vishwa Parekh; Michael A Jacobs
Journal:  Expert Rev Precis Med Drug Dev       Date:  2016-03-31

2.  A fast automatic recognition and location algorithm for fetal genital organs in ultrasound images.

Authors:  Sheng Tang; Si-ping Chen
Journal:  J Zhejiang Univ Sci B       Date:  2009-09       Impact factor: 3.066

3.  Effect of pixel resolution on texture features of breast masses in mammograms.

Authors:  Rangaraj M Rangayyan; Thanh M Nguyen; Fábio J Ayres; Asoke K Nandi
Journal:  J Digit Imaging       Date:  2009-09-12       Impact factor: 4.056

4.  Clinical study of a noninvasive multimodal sono-contrast induced spectroscopy system for breast cancer diagnosis.

Authors:  K Yan; Y Yu; E Tinney; R Baraldi; L Liao
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

5.  Breast mass classification on sonographic images on the basis of shape analysis.

Authors:  Hamid Behnam; Fahimeh Sadat Zakeri; Nasrin Ahmadinejad
Journal:  J Med Ultrason (2001)       Date:  2010-08-07       Impact factor: 1.314

6.  Real-time texture analysis for identifying optimum microbubble concentration in 2-D ultrasonic particle image velocimetry.

Authors:  Lili Niu; Ming Qian; Liang Yan; Wentao Yu; Bo Jiang; Qiaofeng Jin; Yanping Wang; Robin Shandas; Xin Liu; Hairong Zheng
Journal:  Ultrasound Med Biol       Date:  2011-06-17       Impact factor: 2.998

7.  Ultrasound GLCM texture analysis of radiation-induced parotid-gland injury in head-and-neck cancer radiotherapy: an in vivo study of late toxicity.

Authors:  Xiaofeng Yang; Srini Tridandapani; Jonathan J Beitler; David S Yu; Emi J Yoshida; Walter J Curran; Tian Liu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  Characterizing breast masses using an integrative framework of machine learning and CEUS-based radiomics.

Authors:  Bino A Varghese; Sandy Lee; Steven Cen; Amir Talebi; Passant Mohd; Daniel Stahl; Melissa Perkins; Bhushan Desai; Vinay A Duddalwar; Linda H Larsen
Journal:  J Ultrasound       Date:  2022-01-17

Review 9.  Quantification of heterogeneity as a biomarker in tumor imaging: a systematic review.

Authors:  Lejla Alic; Wiro J Niessen; Jifke F Veenland
Journal:  PLoS One       Date:  2014-10-20       Impact factor: 3.240

10.  Robust phase-based texture descriptor for classification of breast ultrasound images.

Authors:  Lingyun Cai; Xin Wang; Yuanyuan Wang; Yi Guo; Jinhua Yu; Yi Wang
Journal:  Biomed Eng Online       Date:  2015-03-24       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.