BACKGROUND: One of the major concerns in replacing creatine kinase MB (CK-MB) with cardiac troponins is the lack of evidence of the ability of troponins to estimate the size of acute myocardial infarction (AMI). We investigated the ability of a single measurement of cardiac troponin T (cTnT) at coronary care unit (CCU) discharge to estimate infarct size and assess left ventricular (LV) function in AMI patients. METHODS: We studied 65 AMI patients in whom infarct size was estimated by CK-MB peak concentrations and gated single-photon emission computed tomography (SPECT) myocardial perfusion using technetium-99m sestamibi and LV function by SPECT imaging. Measurements of cTnT and SPECT were performed 72 h (median) after admission (range, 40-160 h). SPECT was also repeated 3 months later. RESULTS: We found a significant correlation between cTnT and both the peak CK-MB concentrations (r = 0.76; P <0.001) and the perfusion defect size at SPECT (r = 0.62; P <0.001). cTnT was inversely related to LV ejection fraction (LVEF) assessed both early (r = -0.56; P <0.001) and 3 months after AMI (r = -0.70; P <0.001). cTnT >2.98 micro g/L predicted a LVEF <40% at 3 months with a sensitivity of 86.7%, specificity of 81.4%, and a likelihood ratio for a positive test of 4.7 (95% confidence interval, 4.0-5.4). CONCLUSIONS: A single cTnT measurement at CCU discharge after AMI is useful as a noninvasive estimate of infarct size and for the assessment of LV function in routine clinical setting.
BACKGROUND: One of the major concerns in replacing creatine kinase MB (CK-MB) with cardiac troponins is the lack of evidence of the ability of troponins to estimate the size of acute myocardial infarction (AMI). We investigated the ability of a single measurement of cardiac troponin T (cTnT) at coronary care unit (CCU) discharge to estimate infarct size and assess left ventricular (LV) function in AMI patients. METHODS: We studied 65 AMI patients in whom infarct size was estimated by CK-MB peak concentrations and gated single-photon emission computed tomography (SPECT) myocardial perfusion using technetium-99m sestamibi and LV function by SPECT imaging. Measurements of cTnT and SPECT were performed 72 h (median) after admission (range, 40-160 h). SPECT was also repeated 3 months later. RESULTS: We found a significant correlation between cTnT and both the peak CK-MB concentrations (r = 0.76; P <0.001) and the perfusion defect size at SPECT (r = 0.62; P <0.001). cTnT was inversely related to LV ejection fraction (LVEF) assessed both early (r = -0.56; P <0.001) and 3 months after AMI (r = -0.70; P <0.001). cTnT >2.98 micro g/L predicted a LVEF <40% at 3 months with a sensitivity of 86.7%, specificity of 81.4%, and a likelihood ratio for a positive test of 4.7 (95% confidence interval, 4.0-5.4). CONCLUSIONS: A single cTnT measurement at CCU discharge after AMI is useful as a noninvasive estimate of infarct size and for the assessment of LV function in routine clinical setting.
Authors: Adelaide M Arruda-Olson; Véronique L Roger; Allan S Jaffe; David O Hodge; Raymond J Gibbons; Todd D Miller Journal: JACC Cardiovasc Imaging Date: 2011-05
Authors: James Chek; Jaroslav Dusek; Josef Stasek; Jan Vojacek; Josef Bis; Martina Ulrychova; Milos Tichy; Tomas Tomko; Josef Bukac Journal: Heart Vessels Date: 2011-01-26 Impact factor: 2.037
Authors: LeRoy Elazar Rabbani; Carol Waksmonski; Sohah N Iqbal; Jennifer Stant; Robert Sciacca; Mark Apfelbaum; Osman R Sayan; James Giglio; Shunichi Homma Journal: J Thromb Thrombolysis Date: 2007-06-12 Impact factor: 2.300
Authors: Kerstin Kurz; Christian Schild; Peter Isfort; Hugo A Katus; Evangelos Giannitsis Journal: Clin Res Cardiol Date: 2008-10-30 Impact factor: 5.460
Authors: Adelaide M Arruda-Olson; Patricia A Pellikka; Francesca Bursi; Allan S Jaffe; Paula J Santrach; Jan A Kors; Jill M Killian; Susan A Weston; Véronique L Roger Journal: Am Heart J Date: 2008-09-09 Impact factor: 4.749