Literature DB >> 12191724

Comparison of UV- and second derivative-spectrophotometric and LC methods for the determination of valsartan in pharmaceutical formulation.

Sevgi Tatar1, Serap Sağlík.   

Abstract

UV- and second derivative-spectrophotometric and high-performance liquid chromatographic methods for the determination of valsartan in pharmaceutical formulation have been developed. For the first method, UV-spectrophotometry, standard solutions were measured at 205.6 nm. The linearity changes were found to be 2.0-10.0 microg ml(-1) in ethanol and the regression equation was A=1.05 x 10(-1)C+4.26 x 10(-2) (r=0.9997). For the second method, the distances between two extremum values (peak-to-peak amplitudes), 221.6 and 231.2 nm were measured in the second order derivative-spectra of standard solutions. Calibration curves were constructed by plotting d(2)A/dlambda(2) values against concentrations, 0.5-4.0 microg ml(-1) of valsartan standards in ethanol. Regression equation of linear calibration graph was calculated as D=2.9 x 10(-2)C-2.37 x 10(-3) (r=0.9996). The third method was based on high-performance liquid chromatography on C18 column using acetonitrile, phosphate buffer as a mobile phase and losartan as internal standard. Detection was carried out at 265 nm with a UV-detector. The assay was linear over the concentration range at 1.0-5.0 microg ml(-1) and regression equation was found to be A=2.74 x 10(-1)C+2.06 x 10(-2) (r=0.9991). Commercial capsules containing 160 mg valsartan were analysed by the developed methods and the results obtained were compared statistically at 95% confidence level.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12191724     DOI: 10.1016/s0731-7085(02)00360-6

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  Development and validation of a specific stability indicating high performance liquid chromatographic method for valsartan.

Authors:  Ks Rao; N Jena; Meb Rao
Journal:  J Young Pharm       Date:  2010-04

2.  HPTLC Method for the Simultaneous Estimation of Valsartan and Hydrochlorothiazide in Tablet Dosage Form.

Authors:  N J Shah; B N Suhagia; R R Shah; N M Patel
Journal:  Indian J Pharm Sci       Date:  2009-01       Impact factor: 0.975

3.  Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination.

Authors:  Shrikant H Patil; Minakshi V Janjale
Journal:  J Pharm Anal       Date:  2012-04-09

4.  Quality by design approach for development and validation of a RP-HPLC method for simultaneous estimation of xipamide and valsartan in human plasma.

Authors:  Mahmoud M Sebaiy; Sobhy M El-Adl; Mohamed M Baraka; Amira A Hassan; Heba M El-Sayed
Journal:  BMC Chem       Date:  2022-09-20

5.  A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation.

Authors:  Syed Sarim Imam; Abdul Ahad; Mohammed Aqil; Yasmin Sultana; Asgar Ali
Journal:  J Pharm Bioallied Sci       Date:  2013-01

6.  Estimation of Amlodipine Besylate, Valsartan and Hydrochlorothiazide in Bulk Mixture and Tablet by UV Spectrophotometry.

Authors:  Varsha R Galande; K G Baheti; S Indraksha; M H Dehghan
Journal:  Indian J Pharm Sci       Date:  2012-01       Impact factor: 0.975

  6 in total