Literature DB >> 12190908

Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile--Part 2. Cleaning effectiveness and instrumentation results in severely curved root canals of extracted teeth.

E Schäfer1, D Lohmann.   

Abstract

AIM: To determine the cleaning effectiveness and the shaping ability of FlexMaster nickel-titanium rotary instruments and stainless steel hand K-Flexofiles during the preparation of curved root canals in extracted human teeth.
METHODOLOGY: A total of 48 root canals with curvatures ranging between 25 degrees and 35 degrees were divided into two groups of 24 canals. Based on radiographs taken prior to the instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared by FlexMaster instruments using a crown-down preparation technique or by K-Flexofiles using a reaming working motion up to size 35. After each instrument, the root canals were flushed with 5 mL of a 2.5% NaOCl solution and at the end of instrumentation with 5 mL of NaCl. Using the pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. After splitting the roots longitudinally, the amount of debris and smear layer were quantified on the basis of a numerical evaluation scale, using a scanning electron microscope.
RESULTS: Completely cleaned root canals were not found with any of the two instruments. In general, K-Flexofiles resulted in significantly less debris(P < 0.001) and less smear layer (P < 0.05) than Flex-Master instruments, but these differences were not significant in the apical third of the canals (P > 0.05). FlexMaster instruments maintained the original canal curvature significantly better (P < 0.0001) than K-Flexofiles. No significant differences were detected between the instruments (P > 0.05) for the time taken to prepare the canals.
CONCLUSIONS: Under the conditions of this study, K-Flexofiles allowed significantly better canal cleaning than FlexMaster instruments. FlexMaster instruments maintained the original curvature significantly better.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12190908     DOI: 10.1046/j.1365-2591.2002.00515.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  18 in total

1.  Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

Authors:  M Manjunatha; Kini Annapurna; V Sudhakar; Vc Sunil Kumar; Vinay Kumar Hiremath; Ankur Shah
Journal:  J Int Oral Health       Date:  2013-02-26

2.  Effectiveness of XP-endo Finisher, EndoActivator, and File agitation on debris and smear layer removal in curved root canals: a comparative study.

Authors:  Amr M Elnaghy; Ayman Mandorah; Shaymaa E Elsaka
Journal:  Odontology       Date:  2016-05-20       Impact factor: 2.634

3.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

4.  Curvature height and distance of MB canal of mandibular molar with Schneider angle and its comparison with canal access angle.

Authors:  Manjunath H Malur; Anil Chandra
Journal:  J Oral Biol Craniofac Res       Date:  2017-07-17

5.  Comparison of cleaning effectiveness of single rotary file OneShape and reciprocating F2 Protaper with Protaper Universal sequence: A SEM analysis.

Authors:  Adish A Saraf; Anand C Patil; T M Mangala; Rushikesh Mahaparale; Sneha Mali; Sagar Pawar
Journal:  J Oral Biol Craniofac Res       Date:  2020-07-03

6.  Assessing the efficacy of citrus aurantifolia extract on smear layer removal with scanning electron microscope.

Authors:  Behnam Bolhari; Mohammad Reza Sharifian; Mohsen Aminsobhani; Hamid Reza Monsef Esfehani; Pardis Tavakolian
Journal:  Iran Endod J       Date:  2012-06-01

7.  Histological analysis of cleaning efficacy of hand and rotary instruments in the apical third of the root canal: A comparative study.

Authors:  Ashtha Arya; Dildeep Bali; Mandeep S Grewal
Journal:  J Conserv Dent       Date:  2011-07

8.  Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography.

Authors:  Miranda Stavileci; Veton Hoxha; Ömer Görduysus; Ilkan Tatar; Kjell Laperre; Jeroen Hostens; Selen Küçükkaya; Edmond Muhaxheri
Journal:  Med Sci Monit Basic Res       Date:  2015-06-20

9.  Microscopic evaluation of cleaning efficiency of three different nickel-titanium rotary instruments.

Authors:  Maryam Bidar; Saeed Moradi; Maryam Forghani; Salma Bidad; Mahtab Azghadi; Shahrzad Rezvani; Shirin Khoynezhad
Journal:  Iran Endod J       Date:  2010-11-15

10.  A comparative scanning electron microscope investigation of cleanliness of root canals using hand k-flexofiles, rotary race and k3 instruments.

Authors:  Saeed Rahimi; Vahid Zand; Sharhriar Shahi; Sahar Shakouie; Mohammad Forough Reyhani; Mohammad Mohammadi Khoshro; Pardis Tehranchi
Journal:  Iran Endod J       Date:  2008-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.