Literature DB >> 12185121

Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension.

O Schwenn1, R Troost, A Vogel, F Grus, S Beck, N Pfeiffer.   

Abstract

BACKGROUND/AIM: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.
METHODS: 80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pathology except for cataract served as a control group.
RESULTS: The OPA of the POAG group was not statistically significant different from the control group and from the OHT group. However, OPA was statistically significant lower (p<0.01) in the NTG group compared with all other groups. The OPA of the OHT group was slightly higher compared to the healthy volunteers (p=0.09) and to the POAG patients (p=0.09). No statistically significant correlations with blood pressure could be detected. A logistic regression model was established which identified OPA as an independent risk factor for NTG.
CONCLUSIONS: The study demonstrated a decrease in OPA of patients suffering from NTG. Thus, measuring of OPA by the SmartLens dynamic observing tonometer could be helpful in the detection of NTG patients.

Entities:  

Mesh:

Year:  2002        PMID: 12185121      PMCID: PMC1771281          DOI: 10.1136/bjo.86.9.981

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  25 in total

1.  Applanation tonometry and central corneal thickness.

Authors:  N Ehlers; T Bramsen; S Sperling
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-03

2.  Central corneal thickness in low-tension glaucoma.

Authors:  N Ehlers; F K Hansen
Journal:  Acta Ophthalmol (Copenh)       Date:  1974

3.  Some factors in the production of low tension glaucoma.

Authors:  S M Drance
Journal:  Br J Ophthalmol       Date:  1972-03       Impact factor: 4.638

4.  Systemic blood pressure in open-angle glaucoma, low tension glaucoma, and the normal eye.

Authors:  D A Leighton; C I Phillips
Journal:  Br J Ophthalmol       Date:  1972-06       Impact factor: 4.638

5.  Circulating lipoprotein and blood glucose levels in association with low-tension and chronic simple glaucoma.

Authors:  A F Winder
Journal:  Br J Ophthalmol       Date:  1977-10       Impact factor: 4.638

6.  Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic.

Authors:  S Shah; A Chatterjee; M Mathai; S P Kelly; J Kwartz; D Henson; D McLeod
Journal:  Ophthalmology       Date:  1999-11       Impact factor: 12.079

7.  A clinical procedure for the measurements of the ocular pulse-pressure relationship and the ophthalmic arterial pressure.

Authors:  M E Langham; K F To'Mey
Journal:  Exp Eye Res       Date:  1978-07       Impact factor: 3.467

8.  Do patients with low tension glaucoma have particular cardiovascular characteristics?

Authors:  P Demailly; F Cambien; P F Plouin; P Baron; B Chevallier
Journal:  Ophthalmologica       Date:  1984       Impact factor: 3.250

9.  Systemic factors in patients with low-tension glaucoma.

Authors:  I Goldberg; F C Hollows; M A Kass; B Becker
Journal:  Br J Ophthalmol       Date:  1981-01       Impact factor: 4.638

View more
  20 in total

1.  Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver.

Authors:  Umit Aykan; Mesut Erdurmus; Burhan Yilmaz; Ahmet Hamdi Bilge
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

2.  Correlation between biomechanical responses of posterior sclera and IOP elevations during micro intraocular volume change.

Authors:  Hugh J Morris; Junhua Tang; Benjamin Cruz Perez; Xueliang Pan; Richard T Hart; Paul A Weber; Jun Liu
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-01       Impact factor: 4.799

3.  Imaging Corneal Biomechanical Responses to Ocular Pulse Using High-Frequency Ultrasound.

Authors:  Elias Pavlatos; Hong Chen; Keyton Clayson; Xueliang Pan; Jun Liu
Journal:  IEEE Trans Med Imaging       Date:  2018-02       Impact factor: 10.048

4.  Effects of body mass index on intraocular pressure and ocular pulse amplitude.

Authors:  Remzi Karadag; Zeynel Arslanyilmaz; Bahri Aydin; Ibrahim F Hepsen
Journal:  Int J Ophthalmol       Date:  2012-10-18       Impact factor: 1.779

5.  An evaluation of the effects of eyeball structure on ocular pulse amplitude in healthy subjects.

Authors:  Kotaro Ishii; Mikiro Mori; Tetsuro Oshika
Journal:  Int Ophthalmol       Date:  2012-07-20       Impact factor: 2.031

6.  Real-Time In Vivo Intraocular Pressure Monitoring using an Optomechanical Implant and an Artificial Neural Network.

Authors:  Kun Ho Kim; Jeong Oen Lee; Juan Du; David Sretavan; Hyuck Choo
Journal:  IEEE Sens J       Date:  2017-10-05       Impact factor: 3.301

7.  [Ocular pulse amplitude: a new biometrical parameter for the diagnose of glaucoma?].

Authors:  T Romppainen; C Kniestedt; L M Bachmann; J Stürmer
Journal:  Ophthalmologe       Date:  2007-03       Impact factor: 1.059

8.  Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.

Authors:  Michael D Twa; Cynthia J Roberts; Huikai J Karol; Ashraf M Mahmoud; Paul A Weber; Robert H Small
Journal:  J Glaucoma       Date:  2010-08       Impact factor: 2.503

9.  Physiological diurnal variability and characteristics of the ocular pulse amplitude (OPA) with the dynamic contour tonometer (DCT-Pascal).

Authors:  Sayeh Pourjavan; Pierre-Yves Boëlle; Michéle Detry-Morel; Patrick De Potter
Journal:  Int Ophthalmol       Date:  2007-10-23       Impact factor: 2.031

10.  Correlation between ocular pulse amplitude measured by dynamic contour tonometer and visual field defects.

Authors:  Chantal Vulsteke; Ingeborg Stalmans; Steffen Fieuws; Thierry Zeyen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-01-12       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.