Evaluation of extended light path capillary and etched capillary for use in open tubular capillary electrochromatography.

Zhen Liu1, Koji Otsuka, Shigeru Terabe.   

Abstract

Poor sensitivity and low phase ratio are the main drawbacks of open tubular capillary electrochromatography (OTCEC). The poor sensitivity results from the use of narrow bore size capillary, whereas the low phase ratio, which limits the separation capability, is caused by the limited surface area of conventional capillary. Two strategies may be useful to overcome these disadvantages. First, an extended light path (ELP) capillary, which has a bubble cell at the detection point, is used to improve the sensitivity. Secondly, an etched capillary of a 1,000-fold increased surface area is used to enhance the phase ratio. In this work, use of an ELP capillary and an etched capillary in OTCEC was evaluated with a chiral stationary phase of avidin prepared with the physical adsorption method. With a 20 microm I.D. ELP capillary with a 150 microm bubble cell, the peak height was enhanced by 4-10-fold and the corrected peak area was increased by 12-fold relative to a 20 microm I.D. conventional capillary. However, the peak efficiency and resolution decreased noticeably. The phase ratio on the etched capillary was slightly enhanced, by a factor of 1.64 relative to an unetched capillary. Consequently, the separation capability was slightly improved. The increase in the phase ratio was much lower than that expected from the increase in surface area, the reason for which is probably the reduced density of surface silanol group and the generation of nitrogen-containing groups due to the etching process.

Entities:  

Mesh:

Year:  2002        PMID: 12184625     DOI: 10.1016/s0021-9673(02)00662-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Metal organic framework HKUST-1 modified with carboxymethyl-β-cyclodextrin for use in improved open tubular capillary electrochromatographic enantioseparation of five basic drugs.

Authors:  Xiaodong Sun; Yu Tao; Yingxiang Du; Wen Ding; Cheng Chen; Xiaofei Ma
Journal:  Mikrochim Acta       Date:  2019-06-21       Impact factor: 5.833

2.  Maltodextrin-modified graphene oxide for improved enantiomeric separation of six basic chiral drugs by open-tubular capillary electrochromatography.

Authors:  Mingxuan Ma; Ying Xi; Yingxiang Du; Jiangxia Yang; Xiaofei Ma; Cheng Chen
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

3.  Gold nanoparticles coated with a tetramethylammonium lactobionate ionic liquid for enhanced chiral differentiation in open tubular capillary electrochromatography: application to enantioseparation of β-blockers.

Authors:  Xiaodong Sun; Cheng Chen; Xiaoqi Li; Yingxiang Du; Shiyuan Zhao; Zijie Feng
Journal:  Mikrochim Acta       Date:  2020-02-14       Impact factor: 5.833

4.  MIL-53-based homochiral metal-organic framework as a stationary phase for open-tubular capillary electrochromatography.

Authors:  Xiaodong Sun; Bing Niu; Qi Zhang; Qin Chen
Journal:  J Pharm Anal       Date:  2021-12-20